Wandra, Yajiz and Tambunan, Juara Mangapul (2022) STUDI PERHITUNGAN ARUS BOCOR LIGHTNING ARRESTER PADA BAY TRAFO 3 DI GARDU INDUK 150kV SERPONG TANGERANG SELATAN. Diploma thesis, ITPLN.
SKRIPSI 201811279 YAJIZ WANDRA.pdf
Restricted to Registered users only
Download (4MB)
Abstract
Lightning Arrester ialah perangkat yang berperan untuk menjamin kualitas dan keandalan suplay daya ke konsumen. Arrester surja berperan penting dalam membatasi switching dan surja petir yang mengalir dari gardu induk ke tanah. Metode analisis data yang digunakan adalah metode kualitatif, Kemudian data tersebut diolah, dianalisis, dan dievaluasi. Maka di peroleh nilai persentase arus bocor untuk lightning arrester fasa R yaitu sebesar 73%, sedangkan fasa S 716% dan untuk fasa T sebesar 316%. Untuk Nilai persentase arus bocor pada lightning arrester fasa R 73% hal ini menunjukan nilai tersebut berada dibawah ≤90% yang berarti rekomendasi untuk lightning arrester fasa R adalah untuk dilakukan pengujian ulang 1 tahunan. Sedangkan hasil perhitungan persentase arus bocor lightning arrester fasa S 716% dan fasa T 216%, Nilai tersebut berada jauh diatas ≥100% yang berarti rekomendasi untuk lightning arrester fasa S dan Tadalah harus dilakukan penggantian lightning arrester pada fasa S dan T pada bay Trafo 3 Gardu Induk Serpong pada bulan Februari 2022.Berdasarkan hasil pengukuran LCM (leakage current measurement) yang dilaksanakan di Gardu Induk Serpong bay 150kV trafo 3 pada tanggal 24 Februari 2022, di peroleh nilai hasil arus bocor pada lightning arrester fasa R yaitu 110 (μ), fasa S 1074 (μ) dan fasa T 504 (μ).
Lightning Arrester is a device that plays a role in ensuring the quality and reliability of power supply to consumers. The surja arrester plays an important role in limiting the switching and lightning surgery that flows from the substation to the ground. The data analysis method used is a qualitative method, then the data is processed, analyzed, and evaluated. So the percentage value of leakage current for the R phase lightning arrester is 73%, while the S phase is 716% and for the T phase it is 316%. For the leakage current percentage value in the R phase lightning arrester of 73% this shows that the value is below ≤90% which means that the recommendation for the R phase lightning arrester is to be retested 1 yearly. While the results of the calculation of the percentage of leakage current of the S and T phase lightning arresters of 716% and T phases of 216%, the value is far above ≥100% which means that the recommendation for the S and T phase lightning arresters must be replaced in phaseS S and T in the bay of Transformer 3 of the Serpong Substation in February 2022.Based on the results of LCM (leakage current measurement) measurements carried out at the Serpong Bay 150kV Transformer 3 Substation on February 24, 2022,obtained the value of the leakage current result in the lightning arrester phase R, namely 110 (μ), phase S 1074 (μ) and phase T 504 (μ).
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Lighting Arrester, Surja Petir, Arus Bocor. Lighting Arrester, Lightning Surge, Leakage Current. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |