ANALISIS PENGARUH KONTAMINAN NACL & HCL TERHADAP KETAHANAN DAN TEGANGAN TEMBUS ISOLASI UDARA TEGANGAN MENENGAH

Lestari, Widyah Dwi and Alvianingsih, Ginas (2022) ANALISIS PENGARUH KONTAMINAN NACL & HCL TERHADAP KETAHANAN DAN TEGANGAN TEMBUS ISOLASI UDARA TEGANGAN MENENGAH. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201811225 WIDYAH DWI LESTARI.pdf] Text
SKRIPSI 201811225 WIDYAH DWI LESTARI.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Dimasa kini pencemaran lingkungan sudah cukup menghawatirkan, tidak hanya menjadi efek negatif bagi makhluk hidup, adanya pencemaran lingkungan justru juga dapat merusak kondisi fisik dari sebuah benda. Dalam system tenaga listrik sebuah penghantar terbuat dari bahan konduktor, yang di mana bahan konduktor tersebut dapat dipengaruhi oleh keadaan disekitarnya. Penghantar yang berada ditempat tertentu seperti daerah pantai dan daerah pembuangan limbah pabrik sangat mudah terkontaminasi oleh senyawa kimia, seperti NaCl dan HCl dikarenakan daerah-daerah ini dapat menghasilkan senyawa kimia tersebut yang nantinya dapat mengganggu kinerja dari penghantar. Penghantar yang tadinya tidak bermasalah bisa saja terjadi masalah dikarenakan terkontaminasi oleh senyawa kimia dibeberapa daerah tersebut. Hujan merupakan suatu fenomena alam dimana air hujan yang mengandung asam ataupun garam (bersifat elektrolisis) tersebut dapat mengakibatkan tegangan tembus pada penghantar. Tetesan air hujan mengandung asam maupun garam yang dapat menyebabkan terjadinya tegangan tembus. Pada penelitian ini dilakukan pengujian Analisis Pengaruh Kontaminan NaCl & HCl Terhadap Ketahanan Dan Tegangan Tembus Isolasi Udara Tegangan Menengah. Berdasarkan hasil pengujian didapatkan semakin banyak kontaminan yang terkandung semakin mempercepat terjadinya tembus tegangan serta dapat merusak kondisi fisik penghantar.

Nowadays environmental pollution is quite worrying, not only a negative effect on living things, the existence of environmental pollution can also damage the physical condition of an object. In an electric power system, a conductor is made of a conducting material, where the conductor material can be affected by the surrounding conditions. Conductors located in certain places such as coastal areas and factory waste disposal areas are very easily contaminated by chemical compounds, such as NaCl and HCl because these areas can produce these chemical compounds which can interfere with the performance of the conductor. Carriers that were not problematic could have problems because they are contaminated by chemical compounds in some of these areas. Rain is a natural phenomenon where rainwater containing acid or salt (electrolysis) can cause a breakdown voltage in the conductor. Raindrops contain acids and salts that can cause breakdown voltages. In this study, an analysis of the effect of NaCl & HCl contaminants was tested on the Resistance and Translucent Voltage of Medium Voltage Air Insulation. Based on the test results, it is found that the more contaminants contained, the faster the breakdown of the voltage and can damage the physical condition of the conductor.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Isolasi Udara,Penghantar ACCC,Tegangan Tembus,Senyawa NaCL, Senyawa HCl. Air Insulation,ACCC Conductor,Breakdown Voltage,NaCL Compounds, HCl compounds.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro