ANALISIS EFISIENSI SIKLUS BRAYTON PADA BEBAN 100 MW SEBELUM DAN SESUDAH COMBUSTION INSPECTION UNIT 1 BLOK 1 PLTGU PT.PLN NUSANTARA POWER MUARA KARANG

D, Faisal and Nofirman, Nofirman (2024) ANALISIS EFISIENSI SIKLUS BRAYTON PADA BEBAN 100 MW SEBELUM DAN SESUDAH COMBUSTION INSPECTION UNIT 1 BLOK 1 PLTGU PT.PLN NUSANTARA POWER MUARA KARANG. Diploma thesis, ITPLN.

[thumbnail of 201912025 Skripsi Faisal D.pdf] Text
201912025 Skripsi Faisal D.pdf
Restricted to Repository staff only

Download (3MB)

Abstract

Listrik merupakan salah satu kebutuhan yang paling berharga dalam kehidupan
sehari-hari karena kemajuan teknologi. Maka harus diperlukan bagai Upaya utnuk
meningkatkan produksi listrik,caranya adalah membangun pembangkit listrik yang
produktif, Listrik menjadi salah satu kebutuhan esensial dalam kehidupan sehari-hari,
didorong oleh kemajuan teknologi yang pesat. Penggunaan listrik di Indonesia pun
semakin meningkat, diperlukan baik di rumah tangga maupun dalam sektor industri.
Permintaan yang terus bertambah ini membawa konsumsi listrik meningkat dari tahun ke
tahun. Salah satu cara untuk mengetahui produktivitas listrik adalah efisiensi siklus.Jika
nilai efisiensi silus makin tinggi nilainya pada suatu pembangkit,kinerja PLTG akan
semakin maksimal. Apabila efisiensi siklus semakin kecil,dapat dikatakan kinerja PLTG
tidak baik. Untuk menjaga kinerja PLTG perlu dilakukan combustion inspection untuk
menjaga kinerja PLTG agar tetap efisien. Dalam Penelitian ini menggunakan efisiensi
siklus untuk mengetahui peningkatan efisiensi sebelum dan sesudah combustion
inspection pada beban 100 MW dan sebabnya,sehabis dianalisis efisiensi siklus brayton
meningkat 33,2% ke 42,3%.
Electricity is one of the most valuable needs in everyday life because of advances in
technology. So it must be necessary as an effort to increase electricity production, the
way is to build productive power plants. Electricity has become one of the essential needs
in everyday life, driven by progress. fast technology. The use of electricity in Indonesia is
increasing, needed both in households and in the industrial sector. This ever-increasing
demand causes electricity consumption to increase from year to year. One way to determine electricity productivity is cycle efficiency. If the cycle efficiency value is higher in a generator, the PLTG performance will be maximized. The performance of the PLTG is not good. To maintain the performance of the PLTG it is necessary to carry out a combustion inspection to maintain the performance of the PLTG so that it remains efficient. In this research, cycle efficiency was used to determine the increase in efficiency before and after combustion inspection at a load of 100 MW and why, after analyzing the efficiency of the Brayton cycle increased by 33 .2% to 42.3%.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTG, Efisiensi PLTG, Efficiency
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin
Depositing User: Nurul Hidayati
Date Deposited: 28 Aug 2025 01:27
Last Modified: 28 Aug 2025 01:27
URI: https://repository.itpln.ac.id/id/eprint/258