Iqbal, M. Nisfian and Pratama, Arfianto Fendy (2024) ANALISA PENGARUH VARIASI TEKANAN KONDENSOR (VAKUM) TERHADAP HEAT RATE TURBIN PLTU PT PLN UPK NAGAN RAYA. Diploma thesis, ITPLN.
![[thumbnail of 201812035-SKRIPSI_M .NISFIAN IQBAL.pdf]](https://repository.itpln.ac.id/style/images/fileicons/text.png)
201812035-SKRIPSI_M .NISFIAN IQBAL.pdf
Restricted to Repository staff only
Download (3MB)
Abstract
Pada PLTU kondensor merupakan sebagai alat penukar kalor atau heat exchanger. Kondensor berfungsi untukmengkondensasi uap yang berasal dari turbin kemudia diubah menjadi air. Sehingga vakum kondensor harus dijaga parameternya,dikarenakan perubahan nilai vakum kondensor dapat mempengaruhi dari performa turbine uap. Permasalahan yang muncul disebabkan beberapa faktor yaitu didalam tube condenser atau kotornya pipa - pipa kondensor dengan indikator turunnya nilai tekanan vakum, hingga menyebabkan nilai kevakuman kondensor mendekati tekanan atmosfir. Penelitian ini bertujuan untuk mengetahui pengaruh perubahan tekanan vakum terhadap turbine heat rate. Turbine heat rate dapat dilihat dari energi panas yang dimasukkan untuk menghasilkan listrik sebesar 1 kwh. Pada penelitian ini menggunakan beban 45 MW dan 60 MW. Dengan variasi tekanan vakum kondensor sebesar -88,5 kPa, -90,3
kPa, dan -91,7 kPa. Pada hasil penelitian menunjukkan bahwa nilai turbine heat rate
pada beban 45 MW menghasilkan turbine heat rate sebesar 2389,82 kCal/kWh, 2428,49
kCal/kWh, dan 2514,48 kCal/kWh. Sedangkan pada beban 60 MW sebesar 1860,68 kCal/kWh, 1927,09 kCal/kWh, dan 2027,32 kCal/kWh. Sehingga dapat dinyatakan bahwa semakin kecil atau semakin minus tekanan vakum kondensor akan menghasilkan turbine heat rate semakin kecil juga.
At PLTU, the condenser is a heat exchanger. The condenser serves to condense
steam coming from the turbine and then converted into water. So that the condenser
vacuum must be maintained parameters, because changes in the condenser vacuum
value can affect the performance of the steam turbine. The problems that arise are
caused by several factors, namely in the condenser tube or dirty condenser pipes with
indicators of a decrease in the value of vacuum pressure, causing the condenser vacuum
value to approach atmospheric pressure. This study aims to determine the effect of
changes in vacuum pressure on turbine heat rate. Turbine heat rate can be seen from
the heat energy entered to produce electricity of 1 kwh. In this study using loads of 45
MW and 60 MW. With condenser vacuum pressure variations of -88.5 kPa, -90.3 kPa,
and -91.7 kPa. The results showed that the turbine heat rate value at a load of 45 MW
resulted in turbine heat rates of 2389.82 kCal / kWh, 2428.49 kCal / kWh, and 2514.48
kCal / kWh. While at a load of 60 MW of 1860.68 kCal / kWh, 1927.09 kCal / kWh, and
2027.32 kCal / kWh. So it can be stated that the smaller or more minus the condenser
vacuum pressure will produce a smaller turbine heat rate as well.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Kondensor, Tekanan Vakum, Turbine Heat Rate Condenser, Vacuum Pressure, Turbine Heat Rate |
Subjects: | Skripsi Bidang Keilmuan > Teknik Mesin |
Divisions: | Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin |
Depositing User: | Nurul Hidayati |
Date Deposited: | 28 Aug 2025 01:32 |
Last Modified: | 28 Aug 2025 01:32 |
URI: | https://repository.itpln.ac.id/id/eprint/259 |