EVALUASI KINERJA LIGHTNING ARRESTER SEBAGAI PENGAMAN TRANSFORMATOR DARI SURJA PETIR DI GARDU INDUK DURI KOSAMBI 150 KV

Alamanda, Zahra Meilia and Yogianto, Aloysius Agus (2022) EVALUASI KINERJA LIGHTNING ARRESTER SEBAGAI PENGAMAN TRANSFORMATOR DARI SURJA PETIR DI GARDU INDUK DURI KOSAMBI 150 KV. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201811215 ZAHRA MEILIA ALAMANDA.pdf] Text
SKRIPSI 201811215 ZAHRA MEILIA ALAMANDA.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Tegangan berlebih akibat surja petir dapat merusak peralatan pada Gardu Induk seperti transformator daya, hal ini dapat dihindari dengan pemasangan lightning arrester pada gardu induk. Agar dapat melindungi transformator dengan optimal maka perlu dilakukan pengecekan kondisi lightning arrester, salah satunya yaitu pengukuran arus bocor. Pengukuran arus bocor ini dapat dilakukan dengan menggunakan alat LCM (Leakage Current Measurement). Pada skripsi ini penulis akan membahas mengenai kondisi lightning arrester di Gardu Induk Duri Kosambi Bay Trafo dengan mempertimbangkan hasil dari pengukuran LCM dan perhitungan presentase arus bocor serta jarak dari lightning arrester dengan transformator. Pengukuran arus bocor lightning arrester yang didapat, semua lightning arrester yang dipasang pada Bay Trafo GI Duri Kosambi masih memenuhi standar dari pabrik yaitu dibawah 150 µA. Sehingga rekomendasi terhadap lightning arrester yaitu dengan melakukan pengukuran LCM tahunan. Pada penelitian ini, hasil perhitungan variasi jarak maksimum arrester Bay Trafo GI Duri Kosambi, yang termasuk dalam jarak aman untuk dapat melindungi trafo dari gangguan tegangan lebih akibat surja petir berada pada jarak 7,5 m dengan nilai tegangan terminal 550 kV.

Overvoltage due to lightning surges can damage equipment at substations such as power transformers, this can be avoided by installing lightning arresters at substations. In order to protect the transformer optimally, it is necessary to check the condition of the lightning arrester, one of which is the measurement of leakage current. Leakage current measurement can be done using the LCM (Leakage Current Measurement) tool. In this thesis the author will discuss the condition of the lightning arrester at the Duri Kosambi Bay Transformer Substation by considering the results of LCM measurements and calculating the percentage of leakage current and the distance from the lightning arrester to the transformer. The measurement of the lightning arrester leakage current obtained, all the lightning arresters installed on the Bay Transformer GI Duri Kosambi still meet the factory standards, which are below 150 A. So the recommendation for lightning arresters is to take annual LCM measurements. In this study, the results of the calculation of the maximum distance variation of the Bay Transformer GI Duri Kosambi arrester, which is included in the safe distance to be able to protect the transformer from overvoltage disturbances due to lightning surges, is at a distance of 7.5 m with a terminal voltage value of 550 kV.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Surja Petir, Lightning Arrester, LCM, Bay Trafo Gardu Induk Duri Kosambi Lightning surge, Lightning Arrester, LCM, Bay Transformer Substation Duri Kosambi
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro