Nugraha, Nanda Setia and handayani, oktaria (2022) KAJIAN TOTAL HARMONIC DISTORTION (THD) PADA TRANSFORMATOR DISTRIBUSI FA333 DAN FA346 DI PT.PLN(PERSERO) UP3 MADIUN. Diploma thesis, ITPLN.
SKRIPSI 201811185 NANDA SETIA NUGRAHA.pdf
Restricted to Registered users only
Download (4MB)
Abstract
Pada masa sekarang ini penggunaan komputer, lampu LED, printer, UPS (Uninterruptible Power Supplies), lampu ballast (Lampu neon), dan peralatan elektronik lainnya hampir digunakan dalam semua bidang. Peralatan-peralatan tersebut sangat membantu manusia dalam melakukan pekerjaan menjadi lebih mudah dan efisien. Namun di sisi lain pengunaan peralatan tersebut juga dapat meningkatkan penggunaan beban non linier di sisi pelanggan yang menyebabkan timbulnya harmonisa pada sisi distribusi tenaga listrik sehingga mengganggu sistem distribusi tenaga listrik. Penelitian ini bertujuan untuk mengetahui tingkat THDi dan THDv pada transformator FA333 dan FA346 sehingga apabila ditemukan THDi dan THDv yang melebihi batas maka akan dilakukan simulasi perbaikan dengan cara pemasangan filter pasif. Metode pengukuran THDi dan THDv dilakukan pada ketiga fasa transformator FA333 dan FA346 menggunakan alat ukur HIOKI 3286-20 Clamp on hi tester kemudian simulasi perbaikan tingkat THDi dilakukan menggunakan software ETAP16 Hasil pengukuran pada transformator FA333 didapatkan nilai THDi pada fasa R sebesar8,70%, fasa S 7,60% dan fasa T 11,20%. Hasil pengukuran pada transformator FA346 didapatkan nilai THDi pada fasa R sebesar 6,60%, fasa S 9,10% dan fasa T 8,20%. Setelah dilakukan simulasi peredaman filter harmonisa, tingkat THDi pada kedua transformator menjadi turun dibawah standar IEEE 519-1992 yaitu kurang dari 8%.
At this time the use of computers, LED lights, printers, UPS (Uninterruptible Power Supplies), ballast lamps (fluorescent lamps), and other electronic equipment are almost used in all fields. These tools are very helpful for humans to make work easier and more efficient. But on the other hand, the use of these equipment can also increase the use of non-linear loads on the customer side which causes harmonics on the power distribution side to disrupt the electric power distribution system. This study aims to determine the level of THDi and THDv on transformers FA333 and FA346 so that if it is found that THDi and THDv exceed the limit, a simulation of repair will be carried out by installing a passive filter. The THDi and THDv measurement methods were carried out on the three phases of the FA333 and FA346 transformers using the HIOKI 3286-20 Clamp on hi tester then simulation of THDi level improvement was carried out using ETAP16 software. S 7.60% and 11.20% T phase. The measurement results on the FA346 transformer obtained THDi values in the R phase of 6.60%, the S phase of 9.10% and the T phase of 8.20%. After simulating the attenuation of the harmonic filter, the THDi level in both transformers fell below the IEEE 519-1992 standard, which is less than 8%.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Harmonisa, THD, Transformator,Filter Harmonic, THD,Transformers, Filters |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |