Transformator tenaga pada pembangkit listrik merupakan salah satu peralatan utama pembangkit listrik yang sangat penting, terlebih transformator dioperasikan secara terus menerus. Oleh karena itu kinerja transformator perlu diperhatikan agar transformator dapat beroperasi sebagaimana mestinya sesuai dengan masa pakai transformator tersebut. Salah satu faktor yang mempengaruhi berkurangnya kinerja transformator dikarenakan pembebanan pada transformator. Beban yang maksimal atau dikenal dengan beban puncak dapat menyebabkan bertambahnya rugi-rugi tembaga dan susut umur pada transformator. Penelitian ini bertujuan untuk mengetahui pengaruh dari beban puncak terhadap rugi-rugi tembaga dan susut umur transformator tenaga yang ada di PLTU Banten 3 Lontar OMU, dengan menggunakan metode kuantitatif. Berdasarkan hasil perhitungan dan analisis yang dilakukan pembebanan puncak mempengaruhi rugi-rugi tembaga serta susut umur transformator. Semakin besar nilai pembebanan maka semakin besar nilai rugi-rugi tembaga serta laju susut umur transformator. Pada generator transformator unit 1 PLTU Banten 3 Lontar OMU nilai rugi-rugi tembaga tertinggi saat pembebanan puncak terjadi pada tanggal 31 januari 2022 sebesar 485,9136 KW dengan beban puncak 307,33 KW. Sedangkan dari hasil perhitungan susut umur, transformator GT unit 1 PLTU Banten 3 Lontar OMU yang sudah beroperasi dari tahun 2011 mengalami susut umur sebesar 12,8 % dan memiliki sisa umur 8,3276 tahun.
Power Transformers in power plants are one of the main equipment of power plants that are very important, especially transformers that are operated continuously. Therefore, it is necessary to pay attention to the performance of the transformer so that the transformer can operate properly according to the life of the transformer. One of the factors that affect the reduced performance of the transformer is due to the load on the transformer. The maximum load or known as peak load can cause increased copper losses and age losses on the transformer. This study aims to determine the effect of peak load on copper losses and age losses of power transformers in PLTU Banten 3 Lontar OMU, using quantitative methods. Based on the results of calculations and analysis carried out peak loading affects copper losses and transformer’s age losses. The greater the value of the load, the greater the value of copper losses and the rate of age losses of the transformer. In the generator transformer unit 1 PLTU Banten 3 Lontar OMU the highest copper losses when in peak load occurred on January 31, 2022, the amount of the power is 485.9136 KW with a peak load of 307.33 KW. Meanwhile, from the calculation of age loss, the Generator Transformer unit 1 PLTU Banten 3 Lontar OMU has been operating since 2011 has experienced a life loss of 12.8% and has a remaining life of 8.3276 years.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Tranformator,Pembebanan, Rugi-Rugi, Susut umur Transformer, Loading, Loss, Loss of Life |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 22 Oct 2025 02:55 |
| Last Modified: | 22 Oct 2025 02:55 |
| URI: | https://repository.itpln.ac.id/id/eprint/2727 |