Ferdinandus, Christofer and Pramono, Tri Joko (2022) ANALISA PENGARUH KUALITAS ISOLASI PADA TRANSFORMATOR 20kV/400V 250 kVA TERHADAP KONDISI TRANSFORMATOR. Diploma thesis, ITPLN.
SKRIPSI 201811073 CHRISTOFER FERDINANDUS.pdf
Restricted to Registered users only
Download (8MB)
Abstract
Di zaman yang semakin canggih dan maraknya perkembangan teknologi ini membuat kebutuhan masyarakat terhadap energi listrik semakin meningkat. Maka dari itu sangatlah diperlukan perlengkapan kelistrikan yang dapat memenuhi kebutuhan masyarakat terhadap energi listrik ini yaitu transformator. Untuk dapat mempertahankan kualitas dari transformator maka diperlukannya perawatan pada komponen-komponen transformator salah satu diantaranya adalah perawatan terhadap transformator. Untuk mengetahui kelayakan dari isolasi transformator maka dilakukannya pengujian tahanan isolasi dan applied voltage test, pengujian ini dilakukan terhadap transformator yang masih baik kulitas isolasinya dengan yang sudah mengalami penurunan kualitas isolasi. Untuk pengujian tahanan isolasi dan pengujian tegangan terapan menggunakan standar IEC 60076-3. Berdasarkan hasil pengujian yang dilakukan, transformator yang sudah mengalami penurunan kualitas memiliki nilai polaritas indeks yang kecil yaitu pada sisi primer – bumi 1,5 pada sisi sekunder – bumi 1,1 dan pada primer – sekunder 1,1. Setelah dilakukan pengujian tegangan terapan didapatkan bahwa pada transformator yang mengalami penurunan kualitas isolasi memiliki arus bocor sebesar 10,5 mA pada sisi primer dan pada sisi sekunder sebesar 17,2 mA, hal ini dapat mempengaruhi kinerja dari transformator tersebut bahkan dapat membuat kerusakan pada transformator
In an increasingly sophisticated era and the proliferation of technological developments, the public's need for electrical energy is increasing. Therefore, it is necessary to have electrical equipment that can meet the community's needs for electrical energy, namely transformers. To be able to maintain the quality of the transformer, it is necessary to maintain the components of the transformer, one of which is the maintenance of the transformer. To find out the feasibility of transformer isolation, insulation resistance testing and applied voltage tests are carried out, these tests are carried out on transformers that are still of good insulation quality with those that have experienced a decrease in insulation quality. For insulation resistance testing and applied stress testing using the IEC 60076-3 standard. Based on the results of the tests carried out, transformers that have experienced quality degradation have a small polarity index value, namely on the primary – earth side 1.5, secondary – earth 1.1 and primary – secondary 1.1. After testing the applied voltage, it was found that the transformer that experienced a decrease in insulation quality had a leakage current of 10.5 mA on the primary side and on the secondary side of 17.2 mA, this can affect the performance of the transformer and can even cause damage to the transformer.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Isolasi , Pengujian Tahanan Isolasi, Pengujian Tegangan Terapan Transformer, Insulation, Insulastion Resistance Test, Applied Potential Test |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 22 Oct 2025 07:27 |
| Last Modified: | 22 Oct 2025 07:27 |
| URI: | https://repository.itpln.ac.id/id/eprint/2771 |