Umumnya beban yang dilayani oleh suatu transformator pada sistem distribusi akan diusahakan agar tetap pada kondisi seimbang, namun pada kenyataanya ketidakseimbangan beban masih sering terjadi. Diangkatnya judul ini adalah untuk mengetahui besarnya pengaruh dari ketidakseimbangan beban yang sering terjadi pada transformator distribusi digardu Komp. B.P.G UNP terhadap keandalan transformator tersebut. Penelitian ini menggunakan metode observasi untuk memperoleh data gangguan dan data beban transformator. Pada penelitian ini dilakukan perhitungan ketidakseimbangan transformator pada gardu Komp. B.P.G UNP penyulang air tawar dan didapatkan ketidakseimbangan beban pada bulan Februari sebesar 28,3%, pada bulan Maret sebesar 30,6%, dan pada bulan April didapatkan sebesar 45,6%. Untuk menentukan nilai keandalan transformator digunakanlah metode distribusi Weibull dan setelah dilakukan perhitungan pada transformator, didapatkan hasil rata-rata laju kegagalannya adalah 6,15077% per tahun yang berpengaruh terhadap nilai keandalan transformatornya. Nilai dari keandalan transformator tadi didapatkan sebesar 0,349676 dan berdasarkan tingkat keandalan Cronbach’s Alpha transformator ini dapat dikatakan agak handal.

Generally, the load served by a transformer in the distribution system will be endeavored to remain in a balanced condition, but in fact load imbalances still often occur. The appointment of this title is to determine the magnitude of the influence of load imbalances that often occur in distribution transformer at Komp. B.P.G UNP substation on the reliability of the transformer. This study uses the observation method to obtain fault data and transformer load data. In this study, the calculation of the transformer imbalance at the Komp substation was carried out. B.P.G UNP fresh water feeder and found the load imbalance in February was 28.3%, in March it was 30.6%, and in April it was 45.6%. To determine the reliability value of the transformer, the Weibull distribution method is used and after the calculations have been carried out on the transformer, is obtained the average failure rate is 6.15077% per year which affects the reliability value of the transformer. The value of the reliability of the transformer was obtained at 0.349676 and based on the level of reliability of Cronbach's Alpha this transformer can be said to be quite reliable.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator, Ketidakseimbangan, Keandalan Transformator, Distribusi Weibull Transformer, Unbalance, Transformer Reliability, Weibull Distribution
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 22 Oct 2025 07:39
Last Modified: 22 Oct 2025 07:39
URI: https://repository.itpln.ac.id/id/eprint/2775

Actions (login required)

View Item
View Item