Abstract

Susut energi ialah energi salur yang hilang saat pendistribusian listrik ke konsumen, salah satu faktornya pada sisi non teknis, ialah mempengaruhi pengukuran energi listrik pada pelanggan, berdasarkan metode pengumpulan data dari kWh salur dan kWh jual Maret serta upaya penekanan dengan P2TL dari pengukuran kWh pelanggan dan analisis pengujian error meter sebagai identifikasi penyebab susut non teknis yaitu dengan mengukur waktu pemakaian daya aktif pelanggan dan waktu peneraan putaran piringan menggunakan stopwatch. Sebanyak 24 pelanggaran golongan P(II) ditemukan di wilayah UP3 Bintaro, diantaranya mempengaruhi putaran piringan seharusnya 4,80 detik saat peneraan 9,72 detik sehingga meter error tidak sesuai batas kelas meter yaitu kelas 1 adalah ± 1% dan kelas 2 adalah ± 2%. Dari hasil kerugian energi mendapatkan saving kWh sebesar 404.836 kWh dan saving rupiah Rp. 583.946.177, energi yang tersalurkan PT.PLN (persero) UP3 Bintaro bulan Maret mendapatkan nilai susut 9,42%, setelah dilakukan pelaksanaan P2TL susut menurun sebesar 9,19% penekanan susut P2TL berhasil meminimalisir selisih 0,23% dari susut non teknis.

Energy shrinkage is the channel energy lost when distributing electricity to consumers, one of the factors on the non-technical side, is to affect the measurement of electrical energy in customers, based on the method of collecting data from kWh salur and kWh selling March as well as efforts to emphasize with P2TL from customer kWh measurements and meter error testing analysis as an identification of non-technical causes of shrinkage, namely by measuring the customer's active power consumption time and disk rotation handling time using a stopwatch. A total of 24 violations of group P(II) were found in the UP3 Bintaro area, including affecting the rotation of the disk should be 4.80 seconds when the application was 9.72 seconds so that the error meter did not match the meter class limit, namely class 1 is ± 1% and class 2 is ± 2%. From the results of energy losses, you can get a kWh saving of 404,836 kWh and a saving of rupiah of Rp. 583,946,177, the energy channeled by PT. PLN (Persero) UP3 Bintaro in March received a shrinkage value of 9.42%, after the implementation of P2TL shrinkage decreased by 9.19% the emphasis of P2TL shrinkage succeeded in minimizing the difference of 0.23% from non-technical shrinkage.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Susut Non Teknis, P2TL, Nilai Error, Tera Non Technical Shrinkage, P2TL, Error Value, Tera
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 22 Oct 2025 07:38
Last Modified: 22 Oct 2025 07:38
URI: https://repository.itpln.ac.id/id/eprint/2776

Actions (login required)

View Item
View Item