Abstract

Setiap Pembangkit Listrik Tenaga Uap tentu membutuhkan daya dan energi untuk menggerakan peralatan-peralatan listrik di dalamnya. Dimana pada PLTU Banten 3 Lontar terdapat banyak peralatan listrik yang mengkonsumsi energi dalam jumlah besar seperti kipas-kipas untuk pembakaran di boiler. Salah satunya yaitu FD Fan, dimana FD Fan itu sendiri berfungsi untuk menyalurkan udara luar ke dalam ruang pembakaran atau furnace. FD Fan ini digerakkan oleh motor induksi yang membutuhkan daya yang tinggi, yaitu sebesar 500 kW. Sehingga dilakukan pengaplikasian Variable Speed Drive untuk mengurangi konsumsi daya dan energi pada FD Fan dengan melakukan pengujian dengan melepaskan atau membuka damper 100%. Dimana damper itu sendiri berfungsi untuk mengatur flow udara yang masuk ke ruang pembakaran. Dari hasil pengujian dan pengolahan data, didapatkan nilai konsumsi energi yang menurun sebesar 69%. Selain itu penulis juga melakukan perhitungan payback period dengan menghitung estimasi biaya investasi dan menghitung keuntungan biaya konsumsi energi per bulan. Hasil perhitungan payback period yang didapat yaitu biaya investasi akan kembali dalam waktu kurang lebih 5 bulan.

Every Steam Power Plant needs power and energy to operate their electrical devices. In PLTU Banten 3 Lontar there are a lot of electrical devices that consumed power and energy in large amounts, for example boiler furnace’s fans. One of them is FD Fan, where FD Fan itself has the function to blow outside air to the furnace chamber. FD Fan is moved by induction motors that consumed large amounts of energy which is 500 kilowatts. From this matter, the writer wants to apply Variable Speed Drive to decrease the energy consumption of FD Fan with an examination which open the damper of FD Fan into 100% open. Where Damper has the function to control the amount of air that flows through the FD Fan into the furnace chamber. From the examination and data calculation the writer did in this study, the energy consumption is 69% decreased. The writer also did a calculation of payback period with the estimated investment cost and calculate the profit of energy consumption cost per month. The result of the payback period calculation is, the investment cost will return in approximately 5 months.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTU, FD Fan, Variable Speed Drive, Konsumsi Energi, Payback Period. Steam Power Plant, FD Fan, Variable Speed Drive, Energy Consumption, Payback Period.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro