Shalehuddin, Moh and Rahayu, Sofitri (2022) STUDI HARMONISA TEGANGAN DAN ARUS PADA TRANSFORMATOR DI PT. TASINDO TASSA INDUSTRIES TANGERANG. Diploma thesis, ITPLN.
SKRIPSI 201811041 MOH SHALEHUDDIN.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Harmonisa merupakan gangguan yang terjadi pada suatu distribusi listrik. Harmonisa terjadi karena penggunaan beban non linier yang mengakibatkan gelombang hasil keluaran tegangan dan arus mempunyai karakteristrik yang berbeda dengan gelombang masukannya sehingga disebut distorsi. Gelombang harmonisa merupakan gelombang yang terdapat kelipatan frekuensi dari frekuensi fundamental yang disebabkan oleh beban non linier. Adanya harmonisa tegangan dan arus pada suatu sistem ketenagalistrikan yang dapat mempengaruhi kepada kualitas dayanya. Harmonisa memiliki nilai standar yang dimana apabila harmonisa melebihi nilai standar maka dapat mengakibatkan kerusakan pada alat dalam sistem ketenagalistrikan. Adanya harmonisa dapat membuat transformator mengalami over heating yang nantinya akan berakibat pada besarnya rugirugi pada transformator dan juga dapat mempengaruhi menurunnya efisiensi dan kapasitas daya pada transformator. Dari hasil pengukuran harmonisa tegangan dan arus pada PT. Tasindo Tassa Industries didapatkan nilai THDv max sebesar 3.94% dan min 3.05% sehingga dikatakan baik dan tidak melebihi batas standar sebesar 5% mengacu pada (IEEE 519-1992). Sedangkan nilai THDi max sebesar 94.17% dan min 11.18% sangat melampaui batas standar sebesar 15% mengacu pada(IEEE 519-1992).
Harmonics are disturbances that occur in an electrical distribution. Harmonics occur due to the use of non-linear loads which result in the waves resulting from the output of voltage and current have different characteristics from the input waves so they are called distortions. Harmonic waves are waves in which there is a frequency multiple of the fundamental frequency caused by non-linear loads. The existence of voltage and current harmonics in an electrical system that can affect the quality of its power. Harmonics have a standard value which if the harmonics exceed the standard value, it can result in damage to the equipment in the electrical system. The existence of harmonics can make the transformer experience over heating which will later result in the amount of losses in the transformer and can also affect the decrease in efficiency and power capacity in the transformer. From the results of the measurement of voltage and current harmonics in PT. Tasindo Tassa Industries obtained a max THDv value of 3.94% and min 3.05% so it is said to be good and does not exceed the standard limit of 5% referring to (IEEE 519- 1992). While the THDi max value of 94.17 and min 11.18% strongly exceeds the standard limit of 15% referring to (IEEE 519-1992).
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | THD tegangan dan arus, harmonisa, transformator. THD voltage and current, harmonics, transformers. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Oct 2025 03:28 |
| Last Modified: | 23 Oct 2025 03:28 |
| URI: | https://repository.itpln.ac.id/id/eprint/2807 |