Kusuma, R.A. Ilham and Fernandes, Alex (2022) ANALISIS KETIDAKSEIMBANGAN BEBAN TERHADAP EFISIENSI TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO) UNIT LAYANAN PELANGGAN CILEGON BANTEN. Diploma thesis, ITPLN.
SKRIPSI 201811060 R.A. ILHAM KUSUMA.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Seiring perkembangan waktu pembangkit tenaga listrik pasti terdapat kehilangan energi listrik. Oleh karena itu energi listrik perlu adanya antisipasi dan prediksi agar kebutuhan masyarakat terpenuhi dengan baik. salah satu peralatan yang digunakan dalam penyaluran energi adalah transformator distribusi. Transformator merupakan peralatan listrik yang berfungsi untuk menaikkan dan menurunkan tegangan. pada transformator umumnya terjadi berbagai gangguan salah satunya ialah ketidakseimbangan beban. Ketidakseimbangan beban diakibatkan karena tidak meratanya pembagian beban tiap fasanya sehingga arusnya tidak seimbang, maka akan timbul arus pada penghantar netral dan juga menimbulkan arus yang mengalir ke ground, terjadinya hal ini dapat menimbulkan rugi-rugi yang dapat mempengaruhi efisiensi pada transformator. Penelitian ini menggunakan metode analisis kuantitatif dimana angka-angka akan dihitung secara matematis yang mencakup rugi-rugi daya, ketidakseimbangan beban transformator dan efisiensi transformator. Hasil yang didapat pada penelitian kali ini adalah pada ketidakseimbangan beban pada transformator di malam hari sebesar sebesar 20,33% sedangkan pada siang hari sebesar 14% dan di malam hari sudah melebihi standar IEEE std 446-1980. Pada rugi-rugi arus netral yang mengalir ke penghantar netral sebesar 1,15 % pada saat siang hari dan 4,24 % pada saat malam hari. Pada rugi-rugi arus netral yang mengalir ke ground dengan nilai sebesar 6,22 % pada saat siang hari dan 14,41 % pada saat malam hari. Pada efisiensi transformator pada malam hari sebesar 81,33 % lebih kecil dari pada siang hari yaitu sebesar 92,61 % sudah kurang dari SPLN D3.002-1 2007.
As time goes on, power generation will inevitably lose electrical energy. Therefore, electrical energy needs to be anticipated and predicted so that the community's needs are properly met. One of the equipment used in the distribution of energy is a distribution transformer. A transformer is an electrical device that functions to increase and decrease the voltage. In transformers, various disturbances generally occur, one of which is load imbalance. The load imbalance is caused due to the uneven distribution of the load for each phase so that the current is not balanced, there will be a current in the neutral conductor and also cause a current to flow to ground, this occurrence can cause losses that can affect the efficiency of the transformer. This study uses a quantitative analysis method where the numbers will be calculated mathematically which includes power losses, transformer load imbalances and transformer efficiency. The results obtained in this study are that the load imbalance on the transformer at night is 20.33% while during the day it is 14% and at night it exceeds the IEEE std 446-1980 standard. In the neutral current losses that flow to the neutral conductor is 1.15% during the day and 4.24% at night. In the neutral current losses that flow to ground with a value of 6.22% during the day and 14.41% at night. The efficiency of the transformer at night is 81.33 %, smaller than during the day, which is 92.61 %, already less than SPLN D3.002-1 2007.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Ketidakseimbangan, rugi-rugi, Efisiensi Transformer, imbalance, losses, efficienc |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Oct 2025 05:59 |
| Last Modified: | 23 Oct 2025 05:59 |
| URI: | https://repository.itpln.ac.id/id/eprint/2832 |