Nuha, Muhammad Daris and Pahiyanti, Novi Gusti (2022) ANALISIS KONDISI KWH METER ANALOG ANOMALI TEGANGAN RENDAH SATU FASA AREA UP3 BINTARO. Diploma thesis, ITPLN.
SKRIPSI 201811065 MUHAMMAD DARIS NUHA.pdf
Restricted to Registered users only
Download (1MB)
Abstract
KWh meter termasuk ke dalam barang elektronik, yang mana setiap komponennya memiliki keadaan yang beragam. Agar pengukuran penggunaan listik tepat maka kWh meter harus dalam keadaan baik. Pengukuran langsung pada kWh meter merupakan hal penting bagi PT.PLN (persero) khususnya area UP3 Bintaro. Dalam melakukan pengukuran langsung terdapat TS dan TS. TD merupakan tagihan dasar, untuk mendapat nilai tersebut diperlukan data arus, tegangan, dan faktor daya serta konstanta yang tertera pada kWh meter. TS merupakan tagihan susulan, untuk mendapat nilai tersebut diperlukan data seperti TD namun pada TS membutuhkan pewaktuan berputarnya piringan.Jika terdapat anomali maka akan dilakukan tera kWh meter untuk membuktikan kebenaran akan dugaan anomali tersebut. Dalam penelitian ini dilakukan peneraan terhadap beberapa kWh meter dengan merk dan tipe yang sama antara kWh meter dengan kondisi sebenarnya di lapangan dengan kWh meter master milik pihak PLN. Meter yang akan dilakukan peneraan merk Itron dengan tipe M2XS4V3-G dengan 1250 putaran per kWh berada di kelas 2 yang mana ambang batas error kurang lebih 0% - 2.5% dikatakan masih dalam kondisi baik. Terdapat pelanggan 1 terukur tegangan 230 volt, arus 20 ampere, cosphi 1, 123 putaran piringan dengan waktu 60 detik dengan hasil akhir error adalah 68.134 persen. Maka kWh meter pelanggan 1 kondisi tidak baik, wajib dilakukan peneraan.
KWh meters are included in electronic goods, where each component has various conditions. In order for the measurement of electricity usage to be precise, the kWh meter must be in good condition. Direct measurement on the kWh meter is important for PT. PLN (Persero), especially the UP3 Bintaro area. In carrying out direct measurements there are TS and TS. TD is a basic bill, to get this value, current, voltage, and power factor data are needed as well as the constants listed on the kWh meter. TS is a followup bill, to get this value data such as TD is needed but in TS it requires timing of the rotation of the disc. If there is an anomaly, a kWh meter will be calibrated to prove the truth of the alleged anomaly. In this study, several kWh meters with the same brand and type were calibrated with actual conditions in the field with a master kWh meter owned by PLN. The meter that will be calibrated for the Itron brand with type M2XS4V3-G with 1250 revolutions per kWh is in class 2 where the error threshold of approximately 0% - 2.5% is said to be in good condition. There is a customer 1 measurable voltage 230 volts, current 20 amperes, cosphi 1, 123 rotation of the disc with a time of 60 seconds with the final result error is 68.134 percent. So the customer's kWh meter 1 is not in good condition, it must be calibrated..
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | kWh Meter, Pengukuran Langsung, Tera kWh Meter kWh Meter, Direct Measurement, Calibration of kWh Meter |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Oct 2025 06:13 |
| Last Modified: | 23 Oct 2025 06:13 |
| URI: | https://repository.itpln.ac.id/id/eprint/2838 |