Purba, Christoffel Binsar and Suyanto, Heri (2022) ANALISA KINERJA INVERTER PLTS ON GRID DI LABORATORIUM PLTS IT-PLN. Diploma thesis, ITPLN.
SKRIPSI 201811067 CHRISTOFFEL BINSAR PURBA.pdf
Restricted to Registered users only
Download (5MB)
Abstract
Seperti yang diketahui potensi yang dimiliki oleh sumber daya alam Indonesia cukup tinggi dalam hal energy surya apabila dimanfaatkan dengan terukur. Dengan memanfaatkan energi tersebut, pemakaian energi listrik melalui PLN akan berkurang atau terbantu dalam hal pasokan listrik sehingga dapat mengurangi suplai terhadap beban yang ada. Pengaruh temperatur dari sistem fotovoltaik berdampak pada keluaran arus maupun tegangan sehingga output yang dihasilkan akan optimal ataupun tidak. Berdasarkan data iradiasi juga berpengaruh pada keluaran daya oleh inverter. Inverter juga akan bekerja dengan layak ketika nilai standar dari spesifikasi inverter akan bekerja ketika nilai minimum tegangan berada di kisaran 400V-800V dan terbaca dengan baik diatas 800 V sesuai percobaan dan arus dinyatakan sebesar 12,5A sampai 33A dengan data yang didapatkan diatas 12A sehingga kinerja inverter dalam kondisi maksimumnya, namun ketika kondisi iradiasi menurun kinerja inverter akan berkurang dapat dilihat dari daya yang dihasilkan. Temperatur yang terukur berdasarkan data input dari inverter menunjukkan nilai diatas 250C akan membuat kerja inverter sesuai standar. Ketika efisiensi kerja inverter menurun maka daya keluaran tidak akan optimal, namun ketika parameter dari system PV mulai temperature hingga tingkat iradiasi optimal maka imput dan output inverter juga bekerja maksimal.
As is known, the potential of Indonesia's natural resources is quite high in solar energy if it is utilized to the best of its ability. By utilizing this energy, the use of electrical energy through PLN will be reduced or assisted in terms of electricity supply so that it can reduce the supply of existing loads. The effect of temperature from the photovoltaic system has an impact on the current and voltage output so that the resulting output will be optimal or not. Based on the data irradiation also affects the power output by the inverter. The inverter will also work properly when the standard value of the inverter specification will work when the minimum voltage value is in the range of 400V-800V and reads well above 800 V according to the experiment and the current is stated to be 12.5 A to 33 A with the data obtained above. So that the performance of the inverter is in its maximum condition, but when the irradiation condition decreases, the performance of the inverter will decrease, which can be seen from the power generated. The measured temperature based on the input data from the inverter shows a value above 25 0C will make the inverter work according to standard.When the work efficiency of the inverter decreases, the output power will not be optimal. but when the parameters of the PV system start from temperature to optimal irradiation level, the input and output of the inverter also work optimally.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | inverter, efisiensi, daya PLTS inverter, efficiency, power of solar power plant |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Oct 2025 06:20 |
| Last Modified: | 23 Oct 2025 06:20 |
| URI: | https://repository.itpln.ac.id/id/eprint/2840 |