Abstract

Pembangkit Listrik Tenaga Surya (PLTS) 131,3 kWp di PT. Indonesia power Bali merupakan pembangkit listrik yang digunakan untuk menyuplai daya ke beban perusahaan yang terintegrasi hybrid dengan unit Pembangkit Listrik Tenaga Diesel Gas (PLTDG) 200 MW dengan kapasitas terpasang 17 MW sebanyak 12 unit. PLTS di PT. Indonesia Power Bali mulai beroperasi pada tahun 2020. Sehingga belum banyak diketahui tentang nilai efisiensi dan rasio kerja dari suatu sistem PLTS hybrid sehingga perlu dilakukan analisis terkait kinerja dan efisiensi PLTS hybrid di PT. Indonesia Power Bali. Kinerja PLTS dapat dikatakan baik jika nilai performa rasio dari sistem PLTS bernilai 80-90%. Untuk menghitung nilai performa rasio dapat menggunakan perhitungan manual dan simulasi software PVsyst 7.2. Dari perhitungan manual didapatkan hasil pemakaian sendiri untuk hybrid dari PLTDG sebesar 44,867 kWh dengaan hasil efisiensi sebesar 10,24% dan performa rasio sebesar 73,01 % sedangkan hasil perhitungan menggunakan simulasi software PVsyst 7.2 mendapatkan hasil efisiensi sebesar 17,23% dan performa rasio sebesar 80,4%. Hasil perhitungan efisiensi tersebut terdapat selisih sebesar 6,99 % dan 7,3 % untuk performa rasio, sehingga perlu untuk dilakukan peningkatan kinerja sistem PLTS dengan cara melakukan pemeliharaan secara berkala.

Solar Power Plant (PLTS) 131.3 kWp at PT. Indonesia power Bali is a power plant that is used to supply power to the company's loads, which is integrated hybrid with 12 units of Diesel Gas Power Plant (PLTDG) 200 MW with a capacity installed is 17 MW. PLTS at PT. Indonesia Power Bali started operating in 2020. So not much is known about the efficiency value and performance ratio of a PLTS hybrid system, so it is necessary to do an analysis related to the performance and efficiency of PLTS hybrid at PT. Indonesia Power Bali. PLTS performance can be said to be good if the ratio performance value of the PLTS system is 80-90%. To calculate the value of the ratio performance can use manual calculations and simulation software PVsyst 7.2. From manual calculations, the results of self-use for hybrids from PLTDG are 44.867 kWh with efficiency results of 10.24% and ratio performance of 73,01 %, while the results of calculations using PVsyst 7.2 software simulations get efficiency results of 17.23% and ratio performance of 80.4%. The results of the calculation of the efficiency there is a difference of 6.99% and 7.3 % for the ratio performance, so it is necessary to improve the performance of the PLTS system by carrying out regular maintenance.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTS Hybrid, Pemakaian sendiri, efisiensi , performa rasio,PVsyst PLTS Hybrid, Self-use, effisiecy , performance rasio,PVsyst
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 24 Oct 2025 03:27
Last Modified: 24 Oct 2025 03:27
URI: https://repository.itpln.ac.id/id/eprint/2889

Actions (login required)

View Item
View Item