IMPLEMENTASI PENGGUNAAN POLA NON KASKADE PADA RELE ARUS LEBIH DI TRANSFORMATOR 3 GARDU INDUK PONDOK KELAPA 150 kV / 20 kV DALAM MEMPERBAIKI WAKTU BEBAS GANGGUAN

Abidin, Fadly Zidan and Fernandes, Alex (2022) IMPLEMENTASI PENGGUNAAN POLA NON KASKADE PADA RELE ARUS LEBIH DI TRANSFORMATOR 3 GARDU INDUK PONDOK KELAPA 150 kV / 20 kV DALAM MEMPERBAIKI WAKTU BEBAS GANGGUAN. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201811011 FADLY ZIDAN ABIDIN.pdf] Text
SKRIPSI 201811011 FADLY ZIDAN ABIDIN.pdf
Restricted to Registered users only

Download (6MB)

Abstract

Didalam koordinasi pengamanan terdapat dua pengaman yaitu pengaman utama dan pengaman cadangan menggunakan pola cascade, namun pada pola cascade terkadang memberikan pengamanan yang kurang optimal sehingga menyebabkan arus gangguan menembus sisi incoming 20KV. Penulisan skripsi ini bertujuan untuk dapat menambah setting waktu pada rele arus lebih sisi incoming dengan menambahkan pola non kaskade guna meningkatkan pengamanan atau proteksi pada gardu induk terutama transformator. Pada penelitian ini menggunakan metode Kuantitatif melalui proses pengolahan data dan dianalisis permasalahanya. Metode analisis data ini menggunakan pendekatan deskriptif yaitu dilakukan dengan menyampaikan fakta yang telah didapatkan atau diselesaikan. Pola proteksi kaskade atau bertumpuk memberikan waktu bebas gangguan lebih lama sehingga ketika terjadi gangguan hubung singkat tiga fasa dan antar fasa transformator daya sisi incoming merasakan beban stress yang cukup besar dan lebih lama dibandingkan dengan pola non kaskade yang memiliki waktu bebas gangguan lebih singkat karena jika terjadi gangguan hubung singkat tiga fasa atau antar fasa yang cukup besar, maka pola pengaman non kaskade hanya membutuhkan waktu 0,3 detik saja untuk mengirim sinyal ke rele arus lebih sisi incoming 20 kV melalui CBF sehingga nilai beban stress transformator ketika menggunakan pola non kaskade lebih kecil dari pola kaskade.

In the coordination of security, there are two safeguards, namely the main protection and the backup protection using the cascade pattern, but in the cascade pattern sometimes provides suboptimal protection, causing the fault current to penetrate the incoming side of 20kV. The writing of this thesis aims to be able to add time settings to the incoming side of the overcurrent rele by adding a non-cascade pattern to improve security or protection at substations, especially transformers. In this study, it used quantitative methods through the data processing process and analyzed the problem. This data analysis method uses a descriptive approach, which is carried out by conveying facts that have been obtained or resolved. The cascade or stacked protection pattern provides a longer interference-free time so that when there is a three-phase short circuit fault and between phases of the incoming side power transformer, it feels a considerable stress load and is longer than the non-cascade pattern which has a shorter interference-free time because if there is a large enough three-phase or inter-phase short circuit fault, then the non-cascade safety pattern only takes 0.3 seconds to send a signal to the 20 kV incoming side overcurrent rele through the tCBF so that the value of the transformer stress load when using the non-cascade pattern is smaller than the cascade pattern.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Rele Arus Lebih, Kaskade Non Kaskade, Arus Hubung Singkat Overcurrent Rele, Non Cascade Cascade, Short Circuit Current
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 24 Oct 2025 04:14
Last Modified: 24 Oct 2025 04:14
URI: https://repository.itpln.ac.id/id/eprint/2906

Actions (login required)

View Item
View Item