Risqi, Jopri Septria and Sirait, Rummi (2024) ANALISIS KEMURNIAN GAS SF6 UNTUK ISOLASI TERHADAP PENGARUH DAMPAK PMT DI PT. PLN (PERSERO) GI KARET LAMA BAY KAPASITOR 2. Diploma thesis, ITPLN.
SKRIPSI 201911108 JOPRI SEPTRIA RISQI.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Kualitas gas SF6 mempengaruhi kinerja sebagai media isolasi. Parameter kualitas gas SF6 dapat dilihat dari kondisi fisik gas tersebut, yaitu Kemurnian, Kadar Air, Titik Embun, dan Produk Dekomposisi. Kualitas gas SF6 dianalisa dengan alat uji SF6 Analyzer.. Berdasarkan hasil pengukuran dan rata-rata pada setiap kompartemen GI Karet Lama, Penghantar Kapasitor 2, yaitu memiliki Kemurnian 98%; Kadar Air> 1000 ppmV; Titik Embun 3°C dan melakukan penggantian Absorbent pada peralatan Circuit Breaker sehingga kekuatan isolasinya tidak menurun. Serta menganalisa pengaruh dampak PMT nya seperti pengujian Tahanan Kontak dan Pengujian Keserempakan. Penelitian ini dilakukan dengan membandingkan nilai hasil pengujian yang didapat dengan standar nilai pada masing-masing pengujian yang sudah tercantum di SK-DIR 0520 – 2014. Hasil Pengujian tahanan isolasi yang didapat pada masing-masing fasa memiliki nilai diatas 150 M. Sedangkan hasil pengujian tahanan kontak yang dilakukan pada masing-masing fasa diperoleh nilai dibawah 50 µΩ. Pada pengujian keserempakan, hasil perhitungan delta time yang didapat baik pada saat open maupun close masing-masing dibawah 10 ms. PMT yang terpasang pada bay Kapasitor 2 masih dalam kondisi aman dan layak untuk dioperasikan sesuai dengan standar.
The quality of SF6 gas affects its performance as an insulating medium. Parameters of SF6 gas quality can be seen from the physical condition of the gas, namely Purity, Moisture Content, Dew Point, and Decomposition Product. The quality of SF6 gas was analyzed using the SF6 Analyzer. Based on the measurement results and the average for each GIS compartment in Depok Baru, Penghantar Depok I, which has a Purity of 98%; Moisture Content > 1000 ppmV; Dew Point 3°C and replace the Absorbent on the Circuit Breaker equipment so that the insulation strength does not decrease. As well as analyzing the effect of the PMT impact such as the Contact Resistance test and Simultaneous Testing. This research was conducted by comparing the values of the test results obtained with the standard values for each test that have been listed in SK-DIR 0520 – 2014. The results of the insulation resistance test obtained for each phase have a value above 150 M. While the results of the contact resistance test performed on each phase obtained a value below 50 µΩ. In the simultaneity test, the delta time calculation results obtained at both open and close are below 10 ms each. The PMT installed in Depok 1 bay is still in a safe condition and feasible to operate according to standards.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Gas SF6; PMT (Pemisah) SF6 Gas; PMT (Separator) |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 24 Oct 2025 08:13 |
| Last Modified: | 24 Oct 2025 08:13 |
| URI: | https://repository.itpln.ac.id/id/eprint/2941 |