ANALISIS PENGUJIAN TRANSFORMATOR ARUS (CT) PADA BAY PENGHANTAR II DI GARDU INDUK 150 KV CAWANG LAMA

Riyadi, Riyan and Suyanto, Heri (2024) ANALISIS PENGUJIAN TRANSFORMATOR ARUS (CT) PADA BAY PENGHANTAR II DI GARDU INDUK 150 KV CAWANG LAMA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201911053 RIYAN RIYADI.pdf] Text
SKRIPSI 201911053 RIYAN RIYADI.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Pada sistem ketenagalistrikan terus mengalami perkembangan sehingga beban pada sistem gardu induk juga meningkat yang dapat mempengaruhi transformator arus pada gardu induk. Penelitian ini bertujuan untuk mengetahui bagaimana kualitas karakteristik pada transformator arus bay penghantar II di gardu induk 150kv cawang lama dan mengetahui pengaruh buruknya nilai uji terhadap kinerja transformator arus. Dengan menggunakan metode deskriptif kuantitatif pengujian dilakukan dengan menggunakan standar SPLN 42 – 2 : 1992 dan IEEE Std 43™- 2013. Hasil penelitian pada bay penghantar II dilakukan metode pergantian peralatan, transformator arus bay penghantar II pada tahanan isolasinya dan rasio error, dimana transformator arus bay penghantar II cenderung kurang baik dikarenakan nilai tahanan isolasinya 150 MΩ yaitu dengan rata – rata sebesar 615 MΩ dan rasio errornya < 0,2% yaitu dengan rata – rata sebesar – 0,08% Pengukuran berdasarkan standar SPLN 42 – 2 : 1992. dapat disimpulkan bahwa peralatan yang sudah dilakukan metode pergantian peralatan semakin baik tingkat nilai pengujiannya, dan semakin tinggi nilai tahanan isolasinya maka semakin baik isolasi tersebut.

The electricity system continues to develop so that the load on the substation system also increases which can affect the current transformers at the substation. This research aims to determine the quality of the characteristics of the conductor bay II current transformer at the Cawang Lama 150kv substation and determine the effect of poor test values on the performance of the current transformer. Using quantitative descriptive methods, testing was carried out using SPLN 42 – 2 : 1992 and IEEE Std 43™-2013 standards. The results of the research on conductor bay II were carried out using the equipment replacement method, the conductor bay II current transformer on its insulation resistance and error ratio, where the conductor bay II current transformer tends to be poor because the insulation resistance value is 150 MΩ, i.e. with an average of 615 MΩ and the error ratio is

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator Arus, Pengukuran, Karakteristik Current Transformer, Measurement, Characteristics
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 24 Oct 2025 08:40
Last Modified: 24 Oct 2025 08:40
URI: https://repository.itpln.ac.id/id/eprint/2946

Actions (login required)

View Item
View Item