Alfin, Alfin and Pramono, Tri Joko (2024) OIL ISOLATION ANALYSIS OF POWER TRANSFORMER UNIT 3 BASED ON DISSOLVED GAS ANALYSIS TESTING AT ARDIMULYA PEAK SUBSTATION CILEGON TRANSMISSION IMPLEMENTATION UNIT PT. PLN (PERSERO). Diploma thesis, ITPLN.
SKRIPSI 201811287 ALFIN.pdf
Restricted to Registered users only
Download (5MB)
Abstract
Dalam sistem penyaluran energi listrik transformator merupakan salah satu peralatan listrik yang sangat kritis dan tidak lepas dari kemungkinan terjadinya kondisi abnormal dari terjadinya gangguan. Kelainan yang terjadi pada transformator daya dapat terjadi karena gangguan seperti arcing, overheat, dan partial discharge yang akan menghasilkan kandungan gas yang mudah terbakar yang membuat dampak buruk terhadap kinerja transformator. Metode yang digunakan untuk menganalisis isolasi minyak tranformator adalah metode dissolved analysis gas bertujuan untuk mendeteksi adanya kandungan gas yang mudah terbakar yang disebabkan oleh gangguan pada tranformator, jenis kandungan gas yang terdeteksi adalah jenis kandungan gas H2, CH4, C2H6, C2H4, C2H2, CO dan CO2. Hasil penelitian menunjukkan bahwa trafo sering mengalami gangguan busur api pada isolasi minyak transformatornya sehingga isolasi minyak transformator mengalami degradasi dan nilai total gas yang mudah terbakarnya yang terus naik melebihi batas normalnya. Dan dari hasil nilai efisiensi transformator yaitu sebesar 61,9%, dan dari lifetime nya bahwa transformator dapat beroperasi hingga 35 tahun.
In the electrical energy distribution system, transformers are one of the most critical electrical equipment and cannot be separated from the possibility of abnormal conditions from the occurrence of interference. Abnormalities that occur in power transformers can occur due to disturbances such as arcing, overheating, and partial discharge which will produce flammable gas content that makes a negative impact on transformer performance. The method used to analyze the isolation of transformative oil is the dissolved gas analysis method aims to detect the presence of flammable gas content caused by disturbances in the transformer, the type of gas content detected is the type of gas content H2, CH4, C2H6, C2H4, C2H2, CO and CO2. The results showed that transformers often experience arc interference in the isolation of transformer oil so that the isolation of transformer oil is degraded and the total value of combustible gas continues to rise beyond its normal limit. And from the results of the transformer efficiency value of 61.9%, and from its lifetime that the transformer can operate up to 35 years.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | transformator daya, DGA, minyak isolasi, efisiensi trafo, umur trafo transformer power, DGA, oil isolation, efficiency transformer, age transformer |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |