PERANCANGAN SISTEM PENEMPATAN CURRENT LIMITING REACTOR UNTUK MEMBATASI ARUS GANGGUAN PADA GI 150 kV CAWANG LAMA

Sihab, Alwan and Widyastuti, Christine (2024) PERANCANGAN SISTEM PENEMPATAN CURRENT LIMITING REACTOR UNTUK MEMBATASI ARUS GANGGUAN PADA GI 150 kV CAWANG LAMA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201711274 ALWAN SIHAB.pdf] Text
SKRIPSI 201711274 ALWAN SIHAB.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Proteksi sistem tenaga Iistrik adaIah sistem pengaman yang di lakukan terhadap perangkat Iistrik yang terpasang pada sistem tenaga Iistrik. Suatu sistem keIistrikan yang besar harus mempunyai kuaIitas proteksi yang handaI. Contohnya adaIah sistem jaringan transmisi Gardu Induk 150 kV Cawang Lama. Pada tahun 2023 sistem jaringan transmisi Gardu Induk 150 kV Cawang Lama melebihi kapasitas peralatan menyebabkan reactor terbakar.Maka dari itu perIu diIakukannya simulasi terIebih dahulu terhadap sistem transmisi gardu induk cawang lama agar dapat melihat tegangan yang mengaIir pada sistem transmisi Gardu Induk 150 kV Cawang Lama dengan menggunakan software ETAP 16.0.Current Limiting Reactor merupakan peraIatan sistem tenaga Iistrik yang digunakan untuk membatasi arus gangguan hubung singkat agar tidak mengakibatkan kerusakan pada peraIatan tersebut. Pada sistem transmisi Gardu Induk 150 kV terjadi Arus Gangguan Hubung singkat pada GI Cawang Lama dengan niIai 32,4kA yang melebihi kapasitas peralatan Pada GI Cawang Lama sebesar 31,5kA. Lalu pemasangan Currrent Liiting Reactor dengan niIai rating sebesar 1531Ohm.Dapat menurunkan Arus Gangguan Hubung Singkat Menjadi 21,1kA. Sehingga dapat menjaga kapasitas peralatan masih daIam batas aman. HaI ini bermaksud untuk menghindari rusaknya perangkat pada saat terjadinya arus hubung singkat kedepannya.

Electrical power system protection is a security system that applies to electrical devices installed in the electrical power system. A large electrical system must have reliable protection qualities. An example is the Cawang Lama 150 kV main substation transmission network system. In 2023, the transmission network system of the Cawang Lama 150 kV substation exceeds the capacity of the equipment causing the reactor to catch fire. Therefore, it is necessary to conduct a simulation first on the transmission system of the Old Cawang substation in order to see the voltage flowing through the transmission system of the Cawang Lama 150 kV substation. using ETAP 16.0 software. Current Limiting Reactor is an electrical power system equipment that is used to limit short circuit currents so as not to cause damage to the equipment. In the 150 kV substation transmission system, a short circuit fault current occurred at the Cawang Lama GI with a value of 32.4kA which exceeded the equipment capacity at the Old Cawang GI of 31.5kA. Then installing a Current Liiting Reactor with a rating of 1531 Ohm can reduce the Short Circuit Fault Current to 21.1kA. So you can keep equipment capacity within safe limits. This aims to avoid damage to the device when a short circuit occurs in the future

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Sistem Tenaga Listrik , Gangguan Hubung singkat ,Current Limiting Reactor Electric Power Systems, Short Circuit Faults, Current Limiting Reactor
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro