Hyuningkartiko, Ja’far Jamielle and Rahayu, Sofitri (2024) Analisa Pengujian Tegangan Tembus Isolasi Udara Terhadap Pengaruh Variasi Bentuk, Jenis Material, Kondisi, dan Temperatur pada Elektroda. Diploma thesis, ITPLN.
SKRIPSI 202111316 JAFAR JAMIELLE HYUNINGKARTI.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Dalam penyaluran tenaga listrik bertegangan, kemunculan korona merupakan awal terjadinya lompatan muatan listrik yang berujung pada fenomena kegagalan isolasi padat berlanjut pada isolasi udara, pada data statisik PLN 2022 fenomena kegagalalan isolasi ini berpartisipasi pada jumlah gangguan discharging sebesar 64.000 kasus dan data SAIDI sebesar 7,72 jam/pelanggan dimana salah satu penyebab ada pada kegagalan isolasi, sehingga perlu untuk mengetahui pemicu awal kegagalan isolasi dan melakukan kegiatan preventif untuk menghindari kegagalan isolasi udara dikarenakan penggunaan konduktor dan isolator menjadi kesatuan dalam penyaluran tenaga listrik. Awal kemunculan korona hingga terjadinya kegagalan isolasi dipengaruhi oleh beberapa hal seperti bentuk elektroda pada peralatan, jarak antar penghantar dan temperatur alat ataupun sekitar dan kelembaban. Pada skripsi disajikan simulasi dengan pemberian tegangan tinggi pada isolasi udara terhadap variabel pada bentuk elektroda, material, berdebu atau tidak berdebu, dan temperatur 31°C dan 36°C pada elektroda dengan jarak tetap antar elektroda sebesar 2cm. Dari hasil pengujian dapat dilakukan pencarian besaran yang mendukung terjadinya tegangan tembus tersebut berupa energi kinetik,kecepatan elektron, dan membandingkan dengan standar tegangan sesuai standar sekitar 3% . Nilai tegangan tembus isolasi udara pada jarum tembaga 18,13 kV, jarum alluminium 13,28 kV, bola tembaga 37,48, dan bola alluminium 35,63kV. Hasil rata-rata nilai tegangan masih pada acuan 3,1% hingga 3,2% dan sulit nilai tegangan unggul pada material tembaga, bentuk bola,kondisi tanpa debu, dan temperatur elektroda 36°C untuk penerapan yang lebih baik pada isolasi udara.
In the distribution of high-voltage electric power, the appearance of corona is the beginning of a jump in electric charge which leads to the phenomenon of solid insulation failure continuing with air insulation. In the 2022 PLN statistical data, this phenomenon of insulation failure contributed to the number of discharging disturbances amounting to 64,000 cases and SAIDI data amounting to 7.72 hours/customers where one of the causes is insulation failure, so it is necessary to know the initial trigger for insulation failure and carry out preventive activities to avoid air insulation failure due to the use of conductors and insulators as an integral part in the distribution of electrical power. The initial appearance of corona until insulation failure occurs is influenced by several things such as the shape of the electrodes on the equipment, the distance between the conductors and the temperature of the equipment or surroundings and humidity. In this thesis, a simulation is presented by applying high voltage to air insulation for variables such as electrode shape, material, dusty or non-dusty, and temperatures of 31°C and 36°C on the electrodes with a fixed distance between the electrodes of 2cm. From the test results, we can search for quantities that support the breakdown voltage in the form of kinetic energy, electron speed, and compare them with the standard voltage of around 3%. The breakdown voltage value of air insulation on copper needles is 18.13 kV, aluminum needles 13.28 kV, copper balls 37.48, and aluminum balls 35.63kV. The average stress value results are still at the reference level of 3.1% to 3.2% and it is difficult for superior stress values in copper material, spherical shape, dustless conditions, and an electrode temperature of 36°C for better application in air insulation.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Elektroda, Isolasi Udara, Tegangan Tembus Electrodes, Air Insulation, Breakdown Voltage. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 27 Oct 2025 06:15 |
| Last Modified: | 27 Oct 2025 06:15 |
| URI: | https://repository.itpln.ac.id/id/eprint/2971 |