ANALISIS PERFORMANCE KINERJA BATERAI SISTEMOl PLTS OFF-GRID 4OO KWP DI PI]LAU SABIRA

Shidiq, Maulana Fadhlan and Suyanto, Heri (2024) ANALISIS PERFORMANCE KINERJA BATERAI SISTEMOl PLTS OFF-GRID 4OO KWP DI PI]LAU SABIRA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202011261 MAULANA FADHLAN SHIDIQ.pdf] Text
SKRIPSI 202011261 MAULANA FADHLAN SHIDIQ.pdf
Restricted to Registered users only

Download (7MB)

Abstract

Energi surya sangat berperan p€nting dalam kehidupan sehari-hari pada masyarakat di Pulau Sabira. Dengan mernanfaatkan energi surya yang dikonversi menjadi energi listrik :;angat berguna untuk masyarakat Sabira yang rata-rata berprofesi sebagai nelayan, untuk menggunakan pendingin sebagai penlmpanan tangkapan masyarakat sekitar. Pemanl aatan energi tersebut dinamakan Pembangkit Listrik Tenaga Surya. Pembangkit ini terdapat J jenis yaitu PLTS ON-Gnd, PLTS OFF-Grid, dan PLTS Hybrid. Salah satu komponen pcnting dalam Pembangkit Listrik Tenaga Surya adalah baterai. Baterai sangat berfungsi sc.bagai media penyimpanan energi dikarenakan dibutuhkannya ketersediaan energi yang secant terus menerus ketika malam hari maupun pada saat cuaca mendung. Sebagai salah satu komponen yang penting bagi PLTS OFF-Grid balerai sangat diperhatikan maintenanre. Pada penclitian ini membahas mengenai kinerja baterai system 0l pada PLTS di Pulau Sabira menggunakan metode sekunder yaitu pengambilan data yang sudah ada. Beberapa topik penelitian adalah konfigwasi dari susunan baterai pada pembangkit, perhitungan SoC dan DoD pada baterai, serta lama waktu pengisian baterai pada PLTS Pulau Sabira. Dari penelitian didapatkan ratarata nilai SoC pada baterai system 0l adalah 82 %o dan rata-rata nilai DoD dalah l8%. Dengan kapasitas baterai yang digunakan sebesar 620.120 Wh. Dengan menggunakan baterai berjems Lead Acid oPzV 2-1000, untuk mengisi ulang baterai memerlukan waktu 12 jarn jika menggunakan metode s/ow charging, sedangkan jika menggunakan metode fast churging memerlukan waktu 3 jam.

Solar energy plays an important role in the daily life of the people on Sabira Island. By utilizing solar energy which is converted into electrical energy, it is very useful for the Sabira people, who mostly work as fishermen, to use coolers as storage for the local community's catch. Utilization of this energy is called Solar Power Plants. There are 3 types of this generator, namely PLTS ON-Grid, PLTS OFF-Grid, and PLTS Hybrid. One of the important components in a Solar Power Plant is the battery. Batteries really function as an energy storage medium due to the need for continuous energy availability at night or during cloudy weather. As one of the important components for OFF-Grid PLTS, maintenance is very important for batteries. This research discusses the performance of system 01 batteries in PLTS on Sabira Island using secondary methods, namely collecting existing data. Some research topics are the configuration of the battery arrangement in the generator, SoC and DoD calculations on the battery, and the battery charging time at the Sabira Island PLTS. From the research, it was found that the average SoC value for system 01 batteries was 82% and the average DoD value was 18%. With a battery capacity of 620,120 Wh. By using a Lead Acid oPzV 2-1000 battery, recharging the battery takes 12 hours if using the slow charging method, whereas if using the fast charging method it takes 3 hours.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTS. Baterai. Kineia PLTS, Battery, Performance
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro