Pada wilayah di Timika, gangguan dan pembebanan listrik sering terjadi, sehingga memerlukan penelitian dan analisis lebih lanjut. Upaya untuk mengurangi kerugian potensial yang dapat menyebabkan pembebanan berlebih pada transformator daya di Gardu Induk 150 kV Timika dapat menyebabkan peningkatan suhu hot spot pada belitan transformator. Peningkatan suhu ini dapat mengurangi umur transformator dan mengakibatkan kerusakan pada belitan. Pembebanan berlebih dapat disebabkan oleh peningkatan beban konsumsi listrik di Papua, yang dapat terjadi karena pertumbuhan ekonomi dan peningkatan jumlah konsumen. Kemudian dari susut umur transformator dapat menyebabkan kerugian daya yang terjadi pada transformator karena arus dan tahanan pada saluran. Berdasarkan analisis menyimpulkan bahwa meskipun beban dan suhu transformator sangat penting, kondisi operasional saat ini di Gardu Induk Timika tidak menimbulkan risiko signifikan terhadap umur transformator. Kedua transformator beroperasi jauh di bawah kapasitas nominalnya, yang menunjukkan umur perkiraan yang panjang hingga tahun 20,53. Selain itu, suhu hotspot tetap jauh di bawah batas maksimum, memastikan operasi yang aman tanpa risiko kerusakan isolasi atau penurunan umur yang signifikan.

In the Timika region, frequent electrical disturbances and overloading necessitate further research and analysis. Efforts to mitigate potential losses that could cause overloading in power transformers at the 150 kV Timika Substation may lead to an increase in hotspot temperature within the transformer windings. This temperature rise could reduce the transformer's lifespan and cause damage to the windings. Overloading can be attributed to the increased electricity consumption in Papua, driven by economic growth and a rising number of consumers. The aging of transformers may result in power losses due to current and resistance in the transmission lines. The analysis concludes that while transformer load and temperature are crucial, the current operational conditions at the Timika Substation do not pose a significant risk to the transformers' lifespan. Both transformers operate well below their nominal capacity, indicating a long estimated lifespan up to the year 2053. Furthermore, the hotspot temperature remains well below the maximum threshold, ensuring safe operation without the risk of insulation damage or significant reduction in lifespan.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator, Pembebanan, Suhu Hot Spot, Susut Umur. Transformer, Overoading, Hotspot Temperature, Operational Lifespan
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 28 Oct 2025 04:26
Last Modified: 28 Oct 2025 04:26
URI: https://repository.itpln.ac.id/id/eprint/3032

Actions (login required)

View Item
View Item