Sodikin, Muhammad Pikri and Pramono, Tri Joko (2024) PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR PADA GARDU INDUK 150kV DURIKOSAMBI DENGAN MENGGU. Diploma thesis, ITPLN.
SKRIPSI 202011235 MUHAMAMAD PIKRI SODIKIN.pdf
Restricted to Registered users only
Download (9MB)
Abstract
Penelitian ini bertujuan untuk menganalisis pengaruh pembebanan terhadap susut umur transformator pada gardu induk 150 kV Durikosambi menggunakan metode Montsinger. Dalam rangka meningkatkan kapasitas distribusi listrik, transformator dipasang di gardu induk untuk mengubah listrik dari tegangan tinggi (transmisi) menjadi tegangan menengah (distribusi) sebelum sampai ke pelanggan. Transformator memiliki batas umur yang ditentukan, yaitu sekitar 20,55 tahun. Pembebanan yang terjadi sangat berpengaruh terhadap kinerja dan umur transformator. Penelitian ini menggunakan data pembebanan selama satu bulan untuk menghitung susut umur transformator. Hasil penelitian menunjukkan bahwa pada transformator I, perkiraan susut umur sebesar 29,30 tahun; transformator II sebesar 60,60 tahun; transformator III sebesar 32,83 tahun; transformator IV sebesar 39,81 tahun; dan transformator V sebesar 88,23 tahun. Hasil ini menunjukkan variasi dalam susut umur yang disebabkan oleh pembebanan yang berbeda pada setiap transformator.
This research aims to analyze the effect of loading on transformer life loss at the 150 kV Durikosambi substation using the Montsinger method. In order to increase electricity distribution capacity, transformers are installed at substations to change electricity from high voltage (transmission) to medium voltage (distribution) before it reaches customers. Transformers have a specified life limit, which is around 20.55 years. The loading that occurs greatly influences the performance and life of the transformer. This study uses loading data for one month to calculate the shrinkage of transformer life. The results showed that in transformer I, the estimated life shrinkage was 29.30 years; transformer II was 60.60 years; transformer III was 32.83 years; transformer IV was 39.81 years; and transformer V was 88.23 years. These results show variations in shrinkage life caused by different loading on each transformer.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, pembebanan, susut umur, metode montsinger Transformers, loading, life losses, Montsinger method |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 28 Oct 2025 07:24 |
| Last Modified: | 28 Oct 2025 07:24 |
| URI: | https://repository.itpln.ac.id/id/eprint/3046 |