Abstract

Over Current Relay (OCR) merupakan suatu relai yang mempunyai kemampuan untuk mendeteksi kenaikan arus diatas nilai yang ditetapkan, yang dapat terjadi akibat adanya arus hubung singkat atau arus berlebih. Pada GI Cawang Lama terdapat pergantian relai OCR analog menjadi relai digital, dengan beberapa setting parameter. Untuk mengetahui pengaruhnya jenis relai dan setting paramter pada sistem proteksi dilakukan simulasi dengan ETAP 19.0.1. Hasil analisis yang dilakukan menggambarkan kinerja OCR analog dapat bekerja sedikit lebih cepat dibandingkan OCR digital dengan perbandingan waktu kerja pada sisi 150 kV 0,1468 detik dan sisi 20 kV 0,505 detik . Dengan arus hubung singkat pada sisi 150 kV 1,8137 kA dan pada sisi 20 kV 13,59641 kA dengan time dial 0,08 detik dan 0,17 detik dan arus setting 0,693 A dan 0,649 A. Pada saat diberi setting time delay 0 detik, akan membuat relai bekerja secara bersamaan dengan relai differential. Pada saat diberi eror diatas 5%, maka relai akan bekerja lebih lambat dari kondisi normalnya. Sedangkan ketika terjadi eror dibawah 5% maka relai akan bekerja lebih cepat dibandingkan dengan kondisi normalnya. Dengan adanya penelitian ini, dapat diketahui jenis relai yang baik untuk digunakan dan pentingnya setting parameter pada relai agar sistem proteksi dapat berjalan dengan baik.

Over Current Relay (OCR) is a relay capable of detecting an increase in current above a set value, which can occur due to a short circuit or overload current. At GI Cawang Lama, there has been a replacement of analog OCR relays with digital relays, involving several parameter settings. To determine the effect of relay type and parameter settings on the protection system, a simulation was conducted using ETAP 19.0.1. The analysis results indicate that the performance of the analog OCR can operate slightly faster than the digital OCR with a working time comparison on the 150 kV side of 0.1468 seconds and on the 20 kV side of 0.505 seconds. With a short circuit current on the 150 kV side of 1.8137 kA and on the 20 kV side of 13.59641 kA, with a time dial of 0.08 seconds and 0.17 seconds, and a current setting of 0.693 A and 0.649 A. When given a 0-second time delay setting, the relay will operate simultaneously with the differential relay. When given an error above 5%, the relay will operate slower than its normal condition. Conversely, when there is an error below 5%, the relay will operate faster than its normal condition. This study reveals the best type of relay to use and the importance of setting parameters on the relay to ensure the protection system operates effectively..

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Over Current Relay, Pick Up , Time Delay, Transformator Over Current Relay, Pick Up , Time Delay, Transformer
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 28 Oct 2025 08:52
Last Modified: 28 Oct 2025 08:52
URI: https://repository.itpln.ac.id/id/eprint/3075

Actions (login required)

View Item
View Item