ANALISIS PENGARUH JATUH TEGANGAN JARINGAN TEGANGAN RENDAH TERHADAP KEANDALAN JARINGAN DISTRIBUSI PT. PLN PERSERO UP3 CENGKARENG

Adam, Amal Rifai and Kartiria, Kartiria (2024) ANALISIS PENGARUH JATUH TEGANGAN JARINGAN TEGANGAN RENDAH TERHADAP KEANDALAN JARINGAN DISTRIBUSI PT. PLN PERSERO UP3 CENGKARENG. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202011174 AMAL RIFAI ADAM.pdf] Text
SKRIPSI 202011174 AMAL RIFAI ADAM.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Saat ini yang dimana kemajuan teknologi yang semakin pesat, serta kebutuhan akan energi listrik yang semakin besar, maka dibutuhkan juga energi yang andal, sehingga diperlukan juga penelitian yang dapat berguna untuk mengurangi Jatuh Tegangan. Penelitian ini bertujuan untuk mengetahui faktor-faktor yang menyebabkan jatuh tegangan, pengaruh dari terjadinya jatuh tegangan serta langkah-langkah yang perlu dilakukan untuk mengurangi jatuh tegangan pada sistem distribusi ini. Pada penelitian digunakan Metode simulasi ETAP untuk mengukur dan menganalisis jatuh tegangan pada Gardu Distribusi KDR 180 ini. Berdasarkan hasil penelitian yang dilakukan menunjukkan bahwa jatuh tegangan melebihi batas toleransi 10%, terutama pada jurusan 1 yaitu sebesar 12,17% dan pada jurusan 2 sebesar 14,66%. Dampaknya mencakup penurunan efisiensi peralatan, peningkatan suhu penghantar, dan kualitas pelayanan yang menurun. Untuk mengatasi masalah ini, disarankan pemerataan beban, penambahan jurusan baru, dan perbaikan komponen jaringan. Langkah-langkah tersebut bertujuan untuk meningkatkan keandalan sistem distribusi listrik dan efisiensi energi dengan memberikan rekomendasi untuk peningkatan keandalan sistem jaringan distribusi.

At this time where technological advances are increasingly rapid, as well as the need for greater electrical energy, reliable energy is also needed, so research is also needed that can be useful for reducing Voltage Drops. This study aims to determine the factors that cause voltage drop, the effect of voltage drop and the steps that need to be taken to reduce voltage drop in this distribution system. The research used the ETAP simulation method to measure and analyze the voltage drop at the KDR 180 Distribution Substation. Based on the results of the research conducted, it shows that the voltage drop exceeds the tolerance limit of 10%, especially in department 1 which is 12.17% and in department 2 it is 14.66%. The impacts include decreased equipment efficiency, increased conductor temperature, and decreased service quality. To solve this problem, load equalization, addition of new majors, and improvement of network components are recommended. These measures aim to improve the reliability of the electricity distribution system and energy efficiency by providing recommendations for improving the reliability of the distribution network system.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: jatuh tegangan, keandalan jaringan, distribusi listrik, ETAP, efisiensi energi. voltage drop, network reliability, power distribution, ETAP, energy efficiency
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 29 Oct 2025 04:32
Last Modified: 29 Oct 2025 04:32
URI: https://repository.itpln.ac.id/id/eprint/3122