Sistem transmisi merupakan bagian penting dalam sistem tenaga listrik yang berfungsi mengirimkan energi listrik dari pusat pembangkit ke pusat beban. Jaringan transmisi dapat berupa saluran udara, saluran bawah tanah, atau saluran bawah laut. Tegangan yang digunakan dalam sistem transmisi biasanya sangat tinggi, seperti 150kV atau 500kV, untuk mengurangi kerugian daya yang terjadi selama pengiriman. Susut transmisi, yaitu hilangnya energi listrik yang dibangkitkan pada saat disalurkan melalui jaringan transmisi ke gardu induk, menjadi salah satu faktor yang signifikan dalam sistem transmisi. Studi ini menganalisis susut energi pada jaringan tegangan tinggi 150 kV di Gardu Induk Timika Papua. Hasil analisis menunjukkan bahwa susut energi transmisi dan distribusi secara signifikan berkontribusi terhadap total susut energi. Susut energi transmisi dipengaruhi oleh faktor-faktor seperti panjang saluran, jenis kabel, dan kondisi cuaca. Sementara itu, susut energi distribusi dipengaruhi oleh faktor-faktor seperti beban, kualitas jaringan, dan efisiensi transformator. Penelitian ini juga mengidentifikasi faktor-faktor yang menyebabkan penurunan susut energi, seperti peningkatan efisiensi sistem, perbaikan infrastruktur, dan perubahan beban Analisis ini memberikan wawasan yang berharga tentang faktor-faktor yang memengaruhi susut energi dalam sistem tenaga listrik. Hasil analisis ini dapat digunakan untuk meningkatkan efisiensi sistem tenaga listrik, meminimalkan kerugian energi, dan meningkatkan kualitas pelayanan.

The transmission system is an important part of the electric power system which functions to send electrical energy from the generating center to the load center. Transmission networks can be overhead lines, underground lines, or undersea lines. The voltage used in transmission systems is usually very high, such as 150kV or 500kV, to reduce power losses that occur during transmission. Transmission loss, namely the loss of electrical energy generated when it is distributed through the transmission network to the substation, is a significant factor in the transmission system. This study analyzes energy losses in the 150 kV high voltage network at the Timika Papua Main Substation. The analysis results show that transmission and distribution energy losses significantly contribute to total energy losses. Transmission energy losses are influenced by factors such as line length, cable type, and weather conditions. Meanwhile, distribution energy losses are influenced by factors such as load, network quality and transformer efficiency. This research also identifies factors that lead to reduced energy losses, such as increased system efficiency, infrastructure improvements, and load changes. This analysis provides valuable insight into the factors that influence energy losses in electric power systems. The results of this analysis can be used to increase the efficiency of the electric power system, minimize energy losses, and improve service quality

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transmisi, gardu induk, susut energy Transmission, substation, energy loss
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 29 Oct 2025 06:26
Last Modified: 29 Oct 2025 06:26
URI: https://repository.itpln.ac.id/id/eprint/3132

Actions (login required)

View Item
View Item