ANALISIS PENGARUH PARTIAL DISCHARGE PADA SALURAN KABEL TEGANGAN MENENGAH(SKTM) PENYULANG CIREMAI SEGMEN GH MFM-SAN PT PLN (PERSERO) UP3 BANTEN UTARA

Domaski, Rifki Fran and Husada, Hendrianto (2024) ANALISIS PENGARUH PARTIAL DISCHARGE PADA SALURAN KABEL TEGANGAN MENENGAH(SKTM) PENYULANG CIREMAI SEGMEN GH MFM-SAN PT PLN (PERSERO) UP3 BANTEN UTARA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202011187 RIFKI FRAN DOMASKI.pdf] Text
SKRIPSI 202011187 RIFKI FRAN DOMASKI.pdf
Restricted to Registered users only

Download (6MB)

Abstract

Pada sistem distribusi di daerah industri Modern Cikande saat ini hampir keseluruhan menggunakan kabel bawah tanah untuk sistem tegangan menengahnya atau biasa disebut dengan SKTM (Saluran Kabel Tegangan Menengah. PT. PLN (Persero) UP3 Banten Utara memanfaatkan assessment kabel untuk menjaga penyaluran tenaga listrik yang andal dan tetap terjaga keandalannya. Untuk gangguan internal pada kabel bawah tanah biasanya disebabkan oleh aktifitas partial discharge (PD). Partial discharge adalah peluahan elektrik pada medium isolasi yang terdapat di antara dua elektroda yang berbeda tegangan tetapi peluahan tersebut tidak sampai menghubungkan kedua elektroda secara sempurna.Oscillating Wave Test System (OWTS) dapat merekam aktifitas partial discharge dengan memberikan tegangan DAC (Damped Alternating Current) pada sistem kabel. Didapat hasil analisa dari penulis karena banyaknya keluhan yang diadukan oleh pelanggan kepada Pihak PLN karena adanya masalah yang diakibatkan nya oleh Partial Discharge Tersebut. diantara lain memiliki aduan sebanyak 20 gangguan akibat Partial Discharge. dan hasil analisis kondisi kabel penyulang Ciremai Fasa S (L2) bersatus waspada dengan estimasi pemeliharaan 1 Tahun dengan kesimpulan analisis berdasarkan pelepasan tegangan PDIV dan PDEV dan Health Index didapati point nya 2 (Waspada).

In the distribution system in the modern industrial area of Cikande today almost all use underground cables for its medium voltage system or commonly called SKTM (Middle Voltage Cable Channel. PT. PLN (Persero) UP3 North Banten utilizes cable assessment to maintain reliable electricity distribution and maintain reliability. For internal interference in underground cables is usually caused by partial discharge (PD) activity. Partial discharge is the electrical discharge in an insulating medium that is between two electrodes of different voltage but the discharge is not until it connects the two electrodes perfectly. Oscillating Wave Test System (OWTS) can record partial discharge activity by providing DAC (Damped Alternating Current) voltage on the cable system. The results of the analysis were obtained from the author because of the many complaints filed by customers to PLN because of the problems caused by the Partial Discharge, among others, there were 20 complaints due to Partial Discharge, and the results of the analysis of the condition of the Ciremai Fasa S (L2) repeat cable were alerted by the estimated maintenance of 1 year with the conclusion of the analysis based on the release of PDIV voltage and PDEV and Health Index Point is 2 (Dangers)

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Partial Discharge,SKTM,DAC Partial Discharge, SKTM, DAC
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 29 Oct 2025 07:24
Last Modified: 29 Oct 2025 07:24
URI: https://repository.itpln.ac.id/id/eprint/3139

Actions (login required)

View Item
View Item