Abstract

Suatu sistem distribusi harus memiliki keandalan dalam penyuplaian listrik kepada konsumen dimana salah satu indikator dalam melihat keandalan suatu sistem distribusi dengan melihat nilai SAIDI dan SAIFI dimana salah satu faktor yang membuat nilai SAIDI dan SAIFI kurang memenuhi standar dapat disebabkan oleh gangguan eksternal. Ketika melakukan inspeksi ditemukan adanya kelelawar yang bergelantungan pada jaringan tegangan menengah dan mengakibatkan terjadi hubung singkat sayap kelelawar yang bersentuhan dengan fasa dan traves besi. Oleh karena itu dilakukan penggantian traves besi menggunakan traves berbahan fiber yang memiliki sifat isolasi lebih baik, sehingga ketika kelelawar hinggap pada jaringan tegangan menengah lalu membentangkan sayapnya hingga mengenai fasa dan trafes tidak terjadi gangguan hubung singkat pada jaringan tersebut. Setelah melakukan penggantian traves berbahan besi menjadi traves berbahan fiber didapatkan hasil yaitu adanya perubahan jumlah gangguan hubung singkat yang diakibatkan oleh kelelawar pada jaringan tegangan menengah dalam kurun waktu 8 bulan menghasilkan berkurangnya gangguan hubung singkat pada jaringan tegangan menengah akibat kelelawar dari yang sebelumnya terjadi gangguan sebanyak 23 kali dalam 8 bulan menjadi 6 gangguan hubung singkat. Dalam penelitian ini mendapatkan hasil yang dapat digunakan untuk membandingkan hasil penggunaan traves berbahan besi dan traves berbahan fiber dalam mengurangi gangguan hubung singkat akibat hewan pada jaringan tegangan menengah.

A distribution system must have reliability in supplying electricity to consumers, where one of the indicators for assessing the reliability of a distribution system is by looking at the SAIDI and SAIFI values. One factor that can cause the SAIDI and SAIFI values to fall below standards is external disturbances. During an inspection, it was found that bats were hanging on the medium-voltage network, resulting in a short circuit due to the bats' wings coming into contact with the phase and steel truss. Therefore, the steel truss was replaced with a fiber-based truss that has better insulating properties, so when a bat lands on the medium-voltage network and spreads its wings to touch the phase and truss, no short circuit occurs in the network.After replacing the steel truss with the fiber truss, results showed a change in the number of short circuit disturbances caused by bats in the medium-voltage network over a period of 8 months, resulting in a decrease in short circuit disturbances from 23 times in 8 months to 6 short circuits. This study provides results that can be used to compare the effectiveness of using steel trusses and fiber trusses in reducing short circuit disturbances caused by animals in the medium-voltage network.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Hubung Singkat, SAIDI, SAIFI, Traves Short Circuit, SAIDI, SAIFI, Traves
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 03 Nov 2025 04:01
Last Modified: 03 Nov 2025 04:01
URI: https://repository.itpln.ac.id/id/eprint/3270

Actions (login required)

View Item
View Item