Penelitian ini membahas mengenai penggunaan minyak yang digunakan sebagai media isolasi pada transformator karena kebutuhan akan energi listrik semakin meningkat seiring berjalan waktu. Kualitas penyaluran energi listrik perlu diperhatikan berdasarkan kinerja transformator dalam bekerja sebab kehandalan transformator sangat berpengaruh dalam menyuplai energi listrik kepada pelanggan. Untuk menghindari terjadinya kerusakan, maka penggunaan media isolasi sebagai pelindung sangat perlu diperhatikan. Hasil Penelitian yang telah dilakukan mengenai pengaruh kontaminan terhadap minyak kemudian dengan kenaikan tingkat suhu minyak dalam minyak hasil nilai breakdown voltage disebabkan karena adanya pengaruh kontaminan kertas selulosa yaitu terjadi penurunan kualitas nilai breakdown voltage sebesar 32,32 kV (0,5 gram), 23,49 kV (1,5 gram), 18,42 kV (2,5 gram), 15,13 kV (3,5 gram), 11,81kV (4,5 gram) dari penurunan breakdown voltage tersebut untuk data 0,5 gram memiliki breakdown Voltage yang masih sesuai >30kV/2,5mm pada standart SPLN 49 tahun 1982. Berdasarkan perubahan suhu sebesar sekitar 45°C, 55°C, 65°C, 75°C, 85°C pada saat suhu semakin tinggi dapat memperburuk minyak dikarenakan penguapan minyak saat di uji membuat pengembunan di bawah penutup bejana Pada pengujian yang diberikan kontaminan air, dengan nilai breakdown Voltage sebesar 22,21 kV (0,5 ml), 21,16 (1,5 ml), 19,34(2,5 ml), 18,45(3,5 ml), 16,35(4,5 ml). Kontaminan air yang terkandung dapat mempengaruhi breakdown voltage minyak transformator dimana semakin banyak kadar air yang terkandung didalam minyak transformator,maka breakdown voltage minyak transformator akan semakin cepat (buruk). Karna air memiliki sifat sebagai konduktif
This research discusses the use of oil used as an insulating medium in transformers because the need for electrical energy is increasing over time. The quality of electrical energy distribution needs to be considered based on the performance of the transformer in working because the reliability of the transformer is very influential in supplying electrical energy to customers. To avoid damage, the use of insulation media as a protector is very noteworthy. The results of research that has been done on the effect of contaminants on oil then with an increase in the temperature level of the oil in the oil the results of the breakdown voltage value are due to the influence of cellulose paper contaminants, namely a decrease in the quality of the breakdown voltage value of 32, 32 kV (0.5 grams), 23.49 kV (1.5 grams), 18.42 kV (2.5 grams), 15.13 kV (3.5 grams), 11.81kV (4.5 grams) from the decrease in breakdown voltage for data 0.5 grams has a breakdown voltage that is still suitable> 30kV / 2.5mm in SPLN 49 standard 1982. Based on temperature changes of about 45 ° C, 55 ° C, 65 ° C, 75 ° C, 85 ° C when the temperature is getting higher can worsen the oil due to the evaporation of oil when the test makes condensation under the vessel cover In tests given water contaminants, with a breakdown voltage value of 22.21 kV (0.5 ml), 21.16 (1.5 ml), 19.34 (2.5 ml), 18.45 (3.5 ml), 16.35 (4.5 ml). Water contaminants contained can affect the breakdown voltage of transformer oil where the more water content contained in the transformer oil, the faster the breakdown voltage of the transformer oil will be (bad). Because water has properties as conductive
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Isolasi, Kontaminan kertas Selulosa, kontaminan air, suhu, Tegangan Tembus Insulation, Cellulose paper contaminants, water contaminants, temperature, Breakdown Voltage |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 03 Nov 2025 04:23 |
| Last Modified: | 03 Nov 2025 04:23 |
| URI: | https://repository.itpln.ac.id/id/eprint/3277 |