NASUTION, RAFIQA ANNAMIRAH and Pahiyanti, Novi Gusti (2024) PENGARUH PEMBEBANAN TRANSFORMATOR TERHADAP UMUR PAKAI TRANSFORMATOR DISTRIBUSI DI PT PLN ULP MEDAN JOHOR. Diploma thesis, ITPLN.
SKRIPSI 202011116 RAFIQA ANNAMIRAH NASUTION.pdf
Restricted to Registered users only
Download (1MB)
Abstract
Transformator adalah perangkat Listrik yang bekerja berdasarkan prinsip induksi elektromagnetik untuk mentransfer daya listrik dua atau lebih gulungan kawat yang terisolasi. Transformator memiliki umur yang ditentukan oleh pabrikan untuk beroperasi dalam waktu tertentu. Standar (IEC) 354 tahun 1972 menyatakan jika transformator dibebani secara stabil pada daya disuhu lingkungan 20°C, suhu hotspot akan mencapai 98°C dan umur transformator mencapai 20 tahun dengan susut normal sebesar 0,0137% perhari. Tujuan penelitian ini untuk mengetahui besarnya persentase beban trafo, pengaruh pembebanan trafo terhadap umur pakai trafo,dan pengaruh suhu terhadap umur pakai transformator. Setelah dilakukan analisis terhadap empat transformator, ditemukan bahwa tiga transformator yang memiliki beban antara 80% hingga 100%. Metode yang digunakan pada penelitian ini adalah metode kuantitatif deskriptif dengan menghitung persentase beban trafo dan susut umur trafo. Hasil menemukan bahwa trafo JH 544-2 mengalami overload sebesar 143,19%, trafo JH 105-2 juga mengalami overload sebesar 84,76%, trafo JH 121-2 tidak overload (67,76%) begitu juga trafo JH 118-2 (67,90%) setelah dilakukan perhitungan ditemukan perkiraan umur di JH 544-2 yaitu 0,86 tahun sedangkan pada trafo JH 105-2, JH 121-2, JH 118- 2 perkiraan umur trafo >20 tahun. Transformator yang terbebani diatas 100% dari rating daya, terjadi penyusutan umur transformator akibat suhu belitan lebih tinggi dari yang diharapkan.
Transformer is an electrical device that works based on the principle of electromagnetic induction to transfer electrical power between two or more insulated coils of wire. Transformers have a lifespan determined by the manufacturer to operate within a certain time. Standard (IEC) 354 of 1972 states that if the transformer is loaded stably at a power at an ambient temperature of 20°C, the hotspot temperature will reach 98°C and the transformer life will reach 20 years with a normal shrinkage of 0.0137% per day. The purpose of this study was to determine the percentage of transformer load, the effect of transformer loading on transformer life, and the effect of temperature on transformer life. After analyzing four transformers, it was found that three transformers had a load between 80% and 100%. The method used in this study is a descriptive quantitative method by calculating the percentage of transformer load and transformer life shrinkage. The results found that the JH 544-2 transformer experienced an overload of 143.19%, the JH 105-2 transformer also experienced an overload of 84.76%, the JH 121-2 transformer was not overloaded (67.76%) as well as the JH 118-2 transformer (67.90%) after the calculation was carried out, the estimated life of the JH 544-2 was 0.86 years, while the JH 105-2, JH 121-2, JH 118-2 transformers had an estimated life of >20 years. Transformers that are loaded above 100% of the power rating, there is a reduction in the transformer life due to the winding temperature being higher than expected.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Arus, Pembebanan Trafo, susut umur transformator Transformer, Current, Transformer Loading transformer life shrinkage |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 03 Nov 2025 04:29 |
| Last Modified: | 03 Nov 2025 04:29 |
| URI: | https://repository.itpln.ac.id/id/eprint/3279 |