Dermawan, Fathiya Raihani and Koerniawan, Tony (2024) PENGARUH PEMERATAAN BEBAN PADA JARINGAN TEGANGAN RENDAH TERHADAP SUSUT TEKNIS JURUSAN SATU TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO) ULP KOTA DEPOK. Diploma thesis, ITPLN.
SKRIPSI 202011067 FATHIYA RAIHANI DERMAWAN.pdf
Restricted to Registered users only
Download (6MB)
Abstract
Ketidakseimbangan beban merupakan faktor utama pada sistem distribusi yang mengakibatkan terjadinya susut. Di PT. PLN ULP Kota depok khususnya pada salah satu gardu pasangan luar portal AGR terdapat beban tidak seimbang, berdasarkan pengukuran secara langsung pada bulan mei 2024 sehingga mengakibatkan terjadinya susut. Sehingga penulis tertarik untuk melakukan metode penelitian kuantitatif yaitu dengan cara melakukan penyeimbangan beban. Hasil dari penelitian yang penulis lakukan menunjukkan persentase ketidakseimbangan sebelum penyeimbangan beban pada jurusan 1 yaitu sebesar 26,6% dan setelah penyeimbangan yaitu sebesar 2,6 % yang sudah sesuai dengan standart persentase ketidakseimbangan menurut IEEE STD 446-1987. Dan hasil pada susut daya pada jurusan 1 sebelum penyeimbangan beban sebesar 87,89 kW dan setelah penyeimbangan beban sebesar 26,08 kW. Terlihat adanya penurunan nilai susut daya setelah dilakukan penyeiumbangan beban sebesar 1,81 kW atau sebesar 70% sehingga dapat diketahui bahwa adanya pengaruh dari penyeimbangan beban terhadap nilai susut teknis transformator distribusi.
Load imbalance is a major factor in the distribution system which results in shrinkage. In PT PLN ULP Depok City, especially in one of the substations of the outer pair of AGR portals, there is an unbalanced load, based on direct measurements in May 2024, resulting in shrinkage. So the authors are interested in conducting quantitative research methods, namely by balancing the load. The results of the research conducted by the author show that the percentage of imbalance before load balancing in department 1 is 26.6% and after balancing is 2.6% which is in accordance with the standard percentage of imbalance according to IEEE STD 446-1987. And the results on power losses in department 1 before load balancing amounted to 87.89 kW and after load balancing amounted to 26.08 kW. There is a decrease in the value of power shrinkage after load balancing of 1.81 kW or 70% so that it can be seen that there is an influence of load balancing on the value of technical shrinkage of distribution transformers.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Ketidakseimbangan Beban, Susut Daya Transformer, Load Unbalance, Power losses |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 04 Nov 2025 04:20 |
| Last Modified: | 04 Nov 2025 04:20 |
| URI: | https://repository.itpln.ac.id/id/eprint/3333 |