Abdullah, Ronaldo Haycal Firdaus and junaidi, andi (2024) ANALISIS HARMONISA PADA JARINGAN DISTRIBUSI LISTRIK TERHADAP KINERJA TRANSFORMATOR 400 KVA DI UP3 CENGKARENG. Diploma thesis, ITPLN.
SKRIPSI 202011034 RONALDO HAYCAL FIRDAUS ABDULLAH.pdf
Restricted to Registered users only
Download (6MB)
Abstract
PT. PLN (Persero) sebagai penyedia energi listrik di Indonesia menghadapi tantangan dalam memenuhi kebutuhan listrik yang terus meningkat, terutama dengan semakin banyaknya penggunaan beban non-linier. Beban non-linier ini, seperti konverter elektronik, motor drive, dan peralatan elektronik lainnya, menghasilkan arus dan tegangan harmonisa yang dapat mengganggu sistem tenaga listrik dan berakibat pada penurunan kinerja transformator distribusi. Gangguan pada transformator dapat berakibat pada pemadaman listrik dan kerugian ekonomi bagi konsumen. Harmonisa dapat menyebabkan distorsi gelombang arus dan tegangan, gelombang frekuensi kelipatan dari frekuensi fundamental, menurunkan kualitas daya, dan meningkatkan rugi-rugi daya pada transformator. Hal ini dapat menyebabkan transformator mudah panas berlebih dan kerusakan pada transformator. Penelitian ini bertujuan untuk menganalisis harmonisa pada kinerja transformator distribusi di PT. PLN (Persero) UP3 Cengkreng. Hasil pengukuran menunjukkan bahwa nilai THD tegangan dan arus pada gardu DK 60 sebesar 1,16% dan THD arus sebesar 9,15%. Upaya mitigasi harmonisa dilakukan dengan pemasangan filter pasif single tuned harmonisa. Filter ini terdiri dari kapasitor (C), induktor (L), dan resistor (R) dengan nilai masing-masing 714,65 μF, 1,57 mH, dan 0,029 Ω. Hasil analisis menunjukkan bahwa harmonisa menyebabkan penurunan daya mampu transformator berkisar antara 0,50155% sampai dengan 0,50500% dan kenaikan susut berbeban transformator berkisar antara 257,74 kWh sampai dengan 335,44 kWh.
PT PLN (Persero) as a provider of electrical energy in Indonesia faces challenges in meeting the increasing demand for electricity, especially with the increasing use of non-linear loads. These non-linear loads, such as electronic converters, motor drives, and other electronic equipment, produce harmonic currents and voltages that can disrupt the power system and result in decreased performance of distribution transformers. Disturbances in transformers can result in power outages and economic losses for consumers. Harmonics can cause distortion of current and voltage waves, frequency waves that are multiples of the fundamental frequency, reduce power quality, and increase power losses in transformers. This can cause the transformer to overheat easily and damage the transformer. This study aims to analyze harmonics on the performance of distribution transformers at PT PLN (Persero) UP3 Cengkreng. The measurement results show that the THD value of voltage and current at DK 60 substation is 1.16% and THD current is 9.15%. Harmonic mitigation efforts are carried out by installing a single tuned harmonics passive filter. This filter consists of a capacitor (C), inductor (L), and resistor (R) with values of 714,65 μF, 1,57 mH, and 0,029 Ω, respectively. The results of the analysis show that harmonics cause a decrease in transformer capability ranging from 0.50155% to 0.50500% and an increase in transformer load shrinkage ranging from 257.74 kWh to 335.44 kWh.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Harmonisa, Transformator, Beban Non-linier, Dampak Harmonisa, Mitigasi Harmonisa. Harmonics, Transformer, Non-linear Load, Impact of Harmonics, Harmonics Mitigation. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 04 Nov 2025 07:48 |
| Last Modified: | 04 Nov 2025 07:48 |
| URI: | https://repository.itpln.ac.id/id/eprint/3366 |