Peningkatan permintaan energi listrik yang signifikan di Jakarta Barat, khususnya pada daerah padat penduduk, menimbulkan tantangan baru dalam menjaga stabilitas dan keandalan sistem distribusi. Penggunaan transformator yang beroperasi di bawah beban berat dan suhu tinggi menjadi faktor penting yang perlu diperhatikan. Penelitian ini bertujuan untuk mengidentifikasi pengaruh suhu terhadap kinerja transformator dan menganalisis kemungkinan solusi untuk mengoptimalkan sistem distribusi.Penelitian ini menggunakan data historis mengenai suhu dan beban pada transformator di daerah padat penduduk di Jakarta Barat. Data dianalisis untuk mengidentifikasi korelasi antara suhu dan kinerja transformator, termasuk penurunan efisiensi dan keandalan. Berdasarkan hasil analisis, penelitian ini menyoroti perlunya menerapkan strategi manajemen termal yang efektif, termasuk penggunaan sistem pendinginan yang optimal, untuk menjaga performa transformator. Penelitian ini juga mengeksplorasi potensi penggunaan teknologi pengatur suhu berbasis thermovision untuk memantau suhu pada titik panas (hotspot) dan mendistribusikan beban secara lebih merata guna meminimalkan risiko kerusakan dan kegagalan pada transformator.

The significant increase in demand for electrical energy in West Jakarta, especially in densely populated areas, poses new challenges in maintaining the stability and reliability of the distribution system. The use of transformers that operate under heavy loads and high temperatures is an important factor that needs to be considered. This research aims to identify the effect of temperature on transformer performance and analyze possible solutions to optimize distribution systems.This research uses historical data on temperature and load on transformers in densely populated areas in West Jakarta. Data were analyzed to identify correlations between temperature and transformer performance, including decreased efficiency and reliability. Based on the results of the analysis, this study highlights the need to implement an effective thermal management strategy, including the use of an optimal cooling system, to maintain the performance of the transformer. This research also explores the potential use of thermovision-based temperature control technology to monitor temperatures at hot spots (hot spots) and distribute loads more evenly to minimize the risk of damage and failure in transformers.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transfotmator, suhu, sistem distribusi Transformer, Temperatur, Distribution System
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 04 Nov 2025 08:04
Last Modified: 04 Nov 2025 08:04
URI: https://repository.itpln.ac.id/id/eprint/3370

Actions (login required)

View Item
View Item