Abstract

Penggunaan isolasi minyak yang mulai ditinggalkan karna banyak nya laporan gangguan dan tingkat kesulitan ketika pemeliharaan dan perbaikan membuat isolasi minyak mulai perlahan digantikan dengan isolasi XLPE. penelitian ini menganalisis pengaruh tahanan isolasi minyak dan XLPE pada kabel SKTM di dua segment penting: GI Muarakarang ke Gardu MK85 dan segment KPK 33 P – MK136. Fokus utama penelitian adalah membandingkan kinerja kedua jenis isolasi dalam konteks keandalan sistem distribusi listrik. Metode penelitian meliputi pengumpulan dan analisis data frekuensi gangguan, nilai ENS (Energy Not Supplied), recovery time, serta kondisi assessment untuk masing-masing segment. Penelitian ini menggunakan pendekatan kuantitatif dan analisa secara komparatif untuk mengevaluasi efektivitas kedua jenis isolasi. Hasil assessment menunjukkan bahwa isolasi XLPE memiliki kinerja yang lebih baik dibandingkan isolasi minyak. Analisis data mengungkapkan bahwa segment dengan isolasi XLPE mengalami frekuensi gangguan yang lebih rendah. Selain itu, nilai ENS yang tercatat pada segment dengan isolasi XLPE juga lebih rendah, mengindikasikan tingkat keandalan yang lebih tinggi.Penelitian ini juga mengkaji recovery time untuk setiap jenis gangguan, memberikan gambaran komprehensif tentang efisiensi pemulihan sistem. Kondisi assessment kedua segment dianalisis secara mendalam, memberikan wawasan tentang faktor-faktor yang mempengaruhi kinerja isolasi.

The use of oil insulation that is starting to be abandoned due to the many reports of disturbances and the level of difficulty during maintenance and repairs has made oil insulation slowly replaced with XLPE insulation. This study analyzes the effect of oil and XLPE insulation resistance on SKTM cables in two important segments: GI Muarakarang to Gardu MK85 and segment KPK 33 P - MK136. The main focus of the study is to compare the performance of the two types of insulation in the context of the reliability of the electricity distribution system. The research method includes data collection and analysis of disturbance frequency, ENS (Energy Not Supplied) values, recovery time, and assessment conditions for each segment. This study uses a quantitative approach and comparative analysis to evaluate the effectiveness of the two types of insulation. The assessment results show that XLPE insulation performs better than oil insulation. Data analysis reveals that segments with XLPE insulation experience lower disturbance frequencies. In addition, the ENS values recorded on segments with XLPE insulation are also lower, indicating a higher level of reliability. This study also examines the recovery time for each type of disturbance, providing a comprehensive picture of the system's recovery efficiency. The assessment conditions of both segments are analyzed in depth, providing insight into the factors that affect insulation performance.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Tahanan isolasi, XLPE, kabel SKTM, frekuensi gangguan, ENS, recovery time, assessment kabel. Insulation resistance, XLPE, SKTM cable, disturbance frequency, ENS, recovery time, cable assessment.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro