ANALISIS PENGUJIAN TAHANAN ISOLASI DAN PENGUJIAN BREAKDOWN VOLTAGE PADA TRANSFORMATOR IBT 150KV/70KVDI PT PLN (PERSERO) ULTG BIMA

Nabela, Fitrah and Sirait, Rummi (2024) ANALISIS PENGUJIAN TAHANAN ISOLASI DAN PENGUJIAN BREAKDOWN VOLTAGE PADA TRANSFORMATOR IBT 150KV/70KVDI PT PLN (PERSERO) ULTG BIMA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201911147 FITRAH NABELA.pdf] Text
SKRIPSI 201911147 FITRAH NABELA.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Transformator merupakan suatu peralatan utama dalam sistem tenaga listrik yang berfungsi untuk mengkonversi tenaga atau daya listrik dari tegangan tinggi ke tegangan rendah ataupun sebaliknya, untuk mencegah kegagalan operasi dan kerusakan perlu dilakukan pengujian tahanan isolasi. Pelaksanaan pengujian isolasi dilakukan pada GarduInduk Bima menggunakan metode pengujian indeks, dan Rasio tegangan, kualitas tahanan isolasi ini yang akan menjadi penentu kelayakan transformator. Data-data yang diperoleh meliputi hasil dari keempat metode pengujian. Pada metode ini data yangdiolah menggunakan rumus-rumus tertentu dan dianalisa dengan data pengukuran. Hasil penelitian di Gardu Induk Bima menunjukkan (1) Nilai indeks polarisasi masih dalam kondisi baik diatas 1,5% sesuai dengan standar IEEE std 62; (2) Nilai tangen delta masihdalam kondisi baik, hanya terjadi penurunan pada bushing C sebesar 0,7% dan mode CHT sebesar -0,6%; (3) Nilai BDV OLTC menunjukkan kondisi baik karena sesuai dengan standar IEC 60156 yaitu diatas 50 kV; (4) Nilai perbandingan rasiotegangan padabelitan transformator masih dalam kondisi baik karena rasio pengujian menunjukkan nilai tegangan bervariasi pada setiap tap changer yang sesuai denganstandar IEC 60076- 01 yaitu dibawah 0,5%. Sehingga transformator masih dikatakan layak pakai.

A power transformer is the main equipment in an electric power system whosefunction is to convert power or electrical power from high voltage to low voltage or vice versa. To prevent operational failure and damage, it is necessary to test the insulation resistance. Insulation testing is carried out at the Bima Substation using the polarization index testing method, and Voltage Ratio, the quality of this insulation resistance which will determine the suitability of the transformer. The data obtained includes the results of the four test methods. In this method, data is processed using certain formulas and analyzed using measurement data between variables before and after. The results of research at the Bima Substation show (1) The polarization index value is still in good condition above 1.5% in accordance with the IEEE standard std62; (2) The delta tangent value is still in good condition, only a decrease in bushingC of 0.7% and CHT mode of -0.6%; (3) The OLTC BDV value shows good condition because it complies with IEC 60156 standards, namely above 50 kV; (4) The comparison value of the voltage ratio on the transformer winding is still in good condition because the test ratio shows that the voltage value varies on each tap changer in accordance with the IEC 60076-01 standard, namely below 0.5%. So the transformer is still said to be suitable for use

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Tahanan Isolasi, Pengujian Breakdown, Transformator Insulation Resistance, Breakdown Testing, Transformer
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 05 Nov 2025 03:58
Last Modified: 05 Nov 2025 03:58
URI: https://repository.itpln.ac.id/id/eprint/3404

Actions (login required)

View Item
View Item