RAFIQ, MUHAMMAD FAZRI and Hajar, Ibnu (2025) ANALISIS SUSUT ENERGI SISTEM DISTRIBUSI 20 KV PADA PENYULANG C1 CIRACAS PT. PLN (PERSERO) UP3 JAKARTA TIMUR. Diploma thesis, Institut Teknologi PLN.
SKRIPSI 201911031 MUHAMMAD FAZRI RAFIQ.pdf
Restricted to Registered users only
Download (9MB)
Abstract
Dalam jaringan distribusi terdapat beberapa komponen seperti jaringan tegangan menengah dan jaringan tegangan rendah, dimana jaringan tegangan menengah menyediakan energi listrik dari gardu induk (GI) ke trafo distribusi, skala tegangan menengah adalah 20 kV, dan jaringan tegangan rendah akan menggunakan penghantar dari trafo ke trafo distribusi, beban memberikan daya. Susut energi nonteknis sering disebabkan oleh tindakan konsumen, seperti pencurian daya atau penggunaan listrik secara tidak bertanggung jawab, yang dapat meningkatkan jumlah susut. Dengan menghitung kerugian yang terjadi menggunakan rumus daya reaktif dan daya aktif sehingga didapatkan hasil perhitungan susut energi dengan menghitung besar nilai daya aktif atau daya yang terpakai oleh tiap penyulang pada C1 Ciracas selama 24 jam adalah 7.971.840 kWh, Daya Reaktif rugi daya yang dihasilkan tiap penyulang di C1 Ciracas dalah 207.600 Var. Adapun besar nilai energi yang terpakai dari tiap penyulang selama 1 bulan dengan menghitung nilai daya aktif dikalikan dengan pemakaian selama 1 bulan pada C1 Ciracas yaitu 5.739.724,8 kWh. Sehingga didapatkan Total Susut Energi selama 12 bulan pada C1 Ciracas sebanyak 115.634 kWh. Sehingga kerugian yang didapatkan oleh UP3 Ciracas selama 1 tahun sebesar Rp. 168.028.172.
In the distribution network there are several components such as medium voltage networks and low voltage networks, where the medium voltage network provides electrical energy from the substation (GI) to the distribution transformer, the medium voltage scale is 20 kV, and the low voltage network will use conductors from the transformer to the distribution transformer, the load provides power. Non-technical energy losses are often caused by consumer actions, such as power theft or irresponsible use of electricity, which can increase the amount of losses. By calculating the losses that occur using the reactive power and active power formulas, the results of the energy loss calculation are obtained by calculating the value of active power or power used by each feeder at C1 Ciracas for 24 hours is 7,971,840 kWh, Reactive Power power loss generated by each feeder at C1 Ciracas is 207,600 Var. The value of energy used from each feeder for 1 month by calculating the value of active power multiplied by the use for 1 month at C1 Ciracas is 5,739,724.8 kWh. So that the Total Energy Loss for 12 months at C1 Ciracas is 115,634 kWh. So that the loss obtained by UP3 Ciracas for 1 year is Rp. 168,028,172.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Rugi Rugi Daya, Jatuh Tegangan, Losses, Jaringan Tegangan Menengah (JTM), Tap Changer, Kapasitor Ban Power Losses, Voltage Drop, Losses, Medium Voltage Network (JTM), Tap Changer, Tire Capacitor. |
| Subjects: | Bidang Keilmuan > Electrical Engineering Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Budi Herdiansyah |
| Date Deposited: | 06 Nov 2025 03:41 |
| Last Modified: | 06 Nov 2025 03:41 |
| URI: | https://repository.itpln.ac.id/id/eprint/3478 |