ANALISIS PENGARUH PEMBEBANAN TERHADAP EFISIENSI TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO) UP3 KUDUS

Nadhifah, Ulfa and putra, Rizki Pratama (2024) ANALISIS PENGARUH PEMBEBANAN TERHADAP EFISIENSI TRANSFORMATOR DISTRIBUSI DI PT. PLN (PERSERO) UP3 KUDUS. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202211524 ULFA NADHIFAH.pdf] Text
SKRIPSI 202211524 ULFA NADHIFAH.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Seiring dengan perkembangan zaman kebutuhan energi listrik akan terus meningkat, sehingga dalam proses penyaluran energi listrik perlu memperhatikan mutu dan keandalan tenaga listrik. Keseimbangan beban transformator distribusi dalam kondisi ideal merupakan harapan bagi sistem kelistrikan baik dari penyedia tenaga listrik maupun pelanggan. Namun karena beban yang bervariasi dan pengoperasian tidak serempak juga mengakibatkan adanya ketidakseimbangan beban. Tujuan penelitian ini adalah untuk mengetahui pengaruh pembebanan transformator distribusi tiga fasa 100 kVA, 160 KVA, dan 200 kVA di PT. PLN (Persero) UP3 Kudus Area Kudus Kota yang kemudian dianalisis terkait pembebanan, ketidakseimbangan beban, rugi-rugi arus netral, dan efisiensi. Metode penelitian yang digunakan adalah metode kuantitatif dengan cara mengumpulkan data transformator. Dari hasil analisis maka pengaruh beban tidak seimbang terhadap rugi-rugi transformator yaitu semakin tinggi nilai beban tidak seimbang yang dihasilkan oleh arus netral pada transformator distribusi maka semakin tinggi pula nilai rugi-rugi yang diperoleh. Sedangkan pengaruh pembebanan terhadap efisiensi transformator yaitu semakin tinggi nilai pemakaian beban maka akan semakin tinggi pula nilai efisieni transformator. Namun pengaruhnya terhadap transformator itu sendiri yaitu semakin besar beban maka semakin cepat penuaan yang dialami oleh transformator, sehingga umur transformator semakin pendek dan kinerja transformator semakin menurun.

Along with the times the demand for electrical energy will continue to increase, so in the process of distributing electrical energy, it is necessary to pay attention to the quality and reliability of electric power. Distribution transformer load balance under ideal conditions is an expectation for the electricity system from both the electricity provider and the customer. However, because the load varies and the operation is not simultaneous, it also results in load imbalance. The purpose of this research is to determine the effect of loading three-phase distribution transformers 100 kVA, 160 kVA, and 200 kVA at PT. PLN (Persero) UP3 Kudus in Kudus City Area which is then analysed related to loading, load imbalance, neutral current losses, and efficiency. The research method used is a quantitative method by collecting transformer data. From the results of the analysis, the effect of unbalanced load on transformer losses is the higher the value of unbalanced load generated by the neutral current in the distribution transformer, the higher the loss value obtained. While the effect of loading on transformer efficiency is the higher the value of load usage, the higher the value of transformer efficiency. However, the effect on the transformer itself is that the greater the load, the faster the aging experienced by the transformer, so that the life of the transformer is getting shorter and the performance of the transformer is decreasing.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator Distribusi, Pembebanan, Efisiensi Distribution Transformers, Loading, Efficiency
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 06 Nov 2025 04:07
Last Modified: 06 Nov 2025 04:07
URI: https://repository.itpln.ac.id/id/eprint/3491

Actions (login required)

View Item
View Item