Penelitian ini mengidentifikasi faktor-faktor yang mempengaruhi terjadinyasusut energi pada gardu distribusi STN 027 dan menilai efisiensi jaringanteganganrendah di PT. PLN Persero ULP Sentani. Faktor utama yang mempengaruhi susut energimeliputi beban pelanggan, jenis penghantar yang digunakan, dan panjang saluran. Padagardu STN 027, beban total pelanggan mencapai 2106 kWdengan penghantar jenisLVTQ berukuran 70mm² dan 35mm², serta panjang saluran sekitar 1350 meter. Susutenergi yang dihasilkan adalah 266,4 watt pada saluran sepanjang 560 meter, 281,2wattpada saluran sepanjang 500 meter, dan 479,51 watt pada saluran sepanjang300meter,dengan total susut energi sebesar 1027,11 watt. Dengan daya yang disalurkansebesar168277,845 watt, susut energi mencapai 0,6%. Efisiensi jaringan tegangan rendahpadapenelitian ini adalah 99,39%, yang berada dalam batas toleransi PLNmenurut SPLND3.002-2 Tahun 2008, yang menyatakan bahwa efisiensi harus berkisar antara90%hingga 100%. Dengan efisiensi sebesar 99,39%, jaringan distribusi teganganrendahdiPT. PLN Persero ULP Sentani dikategorikan sangat efisien. Hasil ini menunjukkanbahwa meskipun ada susut energi, efisiensi jaringan tetap berada pada tingkat yangsangat baik, memastikan kinerja distribusi listrik yang optimal.

This study identifies the factors influencing energy losses in the STN027distribution substation and evaluates the efficiency of the low voltage networkat PT.PLN Persero ULP Sentani. The main factors affecting energy losses include customerload, the type of conductor used, and the length of the line. At the STN027substation,the total customer load reaches 2106 kW with LVTQ conductors sized 70mm² and35mm², and a line length of approximately 1350 meters. The energy losses are266.4watts for a 560meter line, 281.2 watts for a 500-meter line, and 479.51 watts for a300-meter line, with total energy losses amounting to 1027.11 watts. With a deliveredpowerof 168,277.845 watts, the energy losses are 0.6%. The efficiency of the lowvoltagenetwork in this study is 99.39%, which is within PLN's tolerance limits accordingtoSPLN D3.002-2 of 2008, which stipulates that efficiency should range between90%and 100%. With an efficiency of 99.39%, the low voltage distribution networkat PT.PLN Persero ULP Sentani is categorized as highly efficient. These results indicatethatdespite the energy losses, the network efficiency remains at an excellent level, ensuringoptimal performance of electricity distribution.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Susut,toleransi,SPLN,LVTQ Losses, tolerance, SPLN, LVTQ
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 06 Nov 2025 06:12
Last Modified: 06 Nov 2025 06:12
URI: https://repository.itpln.ac.id/id/eprint/3515

Actions (login required)

View Item
View Item