Dalam Suatu pembangkit, peranan baterai sangat penting untuk menyalurkan sumber arus searah. Apabilah baterai mengalami kerusakan yang mengakibatkan baterai tidak bisa digunakan lagi,maka peran dari suplai baterai akan berkurang.hal ini dapat menyebakan peralatan-peralatan mengalami kerusakan dan gangguan pada penyaluran tenaga listrik.Beban-beban essntial merupakan peralatan-peralatan yang sangat penting yang ada pada pembangkit.beban ini harus selalu di suplai oleh energi listrik dalam keadaan normal maupun tidak normal ( Black out).maka untuk memenui penyaluran kebutuhan sumber arus searah,dibutuhkan pengujian dan umur kapasitasbaterai dalam memenuhi kebutuhan beban-beban essential,sisyem DC pada PT. Puncak Jaya Power Tembagapura timika dimana baterai di humbungkan secara seri dengan beban ketika ketika dalam kondisi normal,namun ketika dalam kondisi tidak normal (Black out) baterai,akan langsung menyuplai beban essential dalam waktuk tertentu. Berdasarkan pengujian kapasitas umur baterai yang berlangsung selama 20 jam,baterai yang memiliki kapasitas baterai yang telah diatur sebesar 230 Ah,nilai tegangan akhir perselnya masih diatas tegangan minimumnya sehingga baterai dapat dinyatakan dalam kondisi baik,dengan kapasitas baterai sebesar 230 Ahyang menyuplai beban essential sebesar 20 A,baterai dapat selama 11,5 jam.
In a power plant,the role of,the battery is very important to distribute direct current source.If the battery is damaged resulting in The battery can not longer so the role of the battery will be reduced. This can cause equipment to malfunction and disruption in the distribution of electric power. Essential expenses are very important Equipment in the plant. This burden must always be supplied by electrical energy normal or not normal ( black out ). so to meet the distribution of current source needs unidirectional, it takes testing and battery capacity life in meet the needs of essential loads DC System at PT.loads.Puncak Jaya Power Tembagapura timika where the battery is connected in seri with the load when under normal conditions. However when in abnormal black out the battery will supply essential, the battery will immediately supply essential loads within a certain time.based on testing capacity Battery life that lasts for 20 hours, a battery that has battery capacity set at 230Ah,rate final voltage per the cell is still above minimum voltage so the battery can be said to be in good condition. Whit a battery capacity of 230 Ah that supplies essential load of 20 A,battery can last for 11,5.hours
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Umur Baterai, Beban Essential, Suplai,Kapasitas Sistem DC. Battery life, Essential load, supply,DC System,Capacity. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 06 Nov 2025 06:16 |
| Last Modified: | 06 Nov 2025 06:16 |
| URI: | https://repository.itpln.ac.id/id/eprint/3517 |