PENGARUH PENGGANTIAN LOAD BREAK SWITCH PDAM MENJADI RECLOSER PDAM TERHADAP NILAI SAIDI SAIFI PADA PENYULANG BRIMOB UNIT LAYANAN PELANGGAN WUA-WUA

Wardhika, Muhamad Alan and Sirait, Rummi (2024) PENGARUH PENGGANTIAN LOAD BREAK SWITCH PDAM MENJADI RECLOSER PDAM TERHADAP NILAI SAIDI SAIFI PADA PENYULANG BRIMOB UNIT LAYANAN PELANGGAN WUA-WUA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202011360 MUHAMAD ALAN WARDHIKA.pdf] Text
SKRIPSI 202011360 MUHAMAD ALAN WARDHIKA.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Indeks Durasi Rata-rata Gangguan Sistem (SAIDI) dan Indeks Frekuensi Rata-rata Gangguan Sistem (SAIFI) adalah dua parameter utama yang digunakan untuk mengukur keandalan sistem. Pada periode januari – Desember 2023 nilai SAIDI SAIFI pada penyulang Brimob dinilai tinggi. Nilai SAIDI adalah 8,714 menit/pelanggan dan nilai SAIFI adalah 40,02 kali/pelanggan sehingga dilakukan penggantian LBS menjadi Recloser pada keypoint LBS PDAM yang bertujuan untuk menurunkan nilai SAIDI SAIFI pada penyulang Brimob. Metode penelitian meliputi pengumpulan data gangguan dan analisis perubahan nilai SAIDI dan SAIFI pada periode 3 bulan setelah penggantian peralatan dan digunakan metode peramalan regresi linear dan Moving Average untuk mengetahui kemungkinan nilai SAIDI SAIFI pada periode Juni sampai dengan Desember 2024 yang bertujuan untuk mengetahui pengaruh/keefektifitasan penggantian LBS PDAM menjadi Recloser PDAM. Hasil penelitian yang telah dilakukan dengan membandingkan nilai SAIDI SAIFI 2023 dan 2024 menunjukkan bahwa penggantian LBS dengan Recloser dapat menurunkan nilai SAIDI dari 8,71 menjadi 1,08 dan nilai SAIFI dari 40,02 menjadi 38,61. Ini menunjukkan bahwa penurunan durasi dan frekuensi pemadaman dipengaruhi oleh penggantian LBS dengan Recloser. Penelitian ini dilakukan di PT. PLN (Persero) ULP Wua-Wua Maret hingga Mei 2024. Penelitian ini diharapkan dapat memberikan kontribusi dalam peningkatan keandalan sistem distribusi energi listrik di masa mendatang.

System Interruption Average Duration Index (SAIDI) and System Interruption Average Frequency Index (SAIFI) are two main parameters used to measure system reliability. In the period January – December 2023, the SAIDI SAIFI value for Brimob feeders is considered high. The SAIDI value is 8.714 minutes/customer and the SAIFI value is 40.02 times/customer so that the LBS is replaced with a Recloser at the PDAM LBS keypoint which aims to reduce the SAIDI SAIFI value on the Brimob feeder. The research method includes collecting disturbance data and analyzing changes in SAIDI and SAIFI values in the 3 month period after equipment replacement and using linear regression and Moving Average forecasting methods to determine possible SAIDI SAIFI values in the period June to December 2024 which aims to determine the effect/effectiveness of the replacement LBS PDAM becomes Recloser PDAM. The results of research conducted by comparing the 2023 and 2024 SAIDI SAIFI values show that replacing LBS with Recloser can reduce the SAIDI value from 8.71 to 1.08 and the SAIFI value from 40.02 to 38.61. This shows that the reduction in the duration and frequency of outages is influenced by replacing the LBS with a Recloser. This research was conducted at PT. PLN (Persero) ULP Wua-Wua March to May 2024. This research is expected to contribute to increasing the reliability of the electrical energy distribution system in the future.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: SAIDI, SAIFI, LBS, Recloser SAIDI, SAIFI, LBS, Recloser
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 06 Nov 2025 08:04