ANALISA DALAM PERANCANGAN INSTALASI LISTRIK MESIN CRUSHER BATUBARA DI PLTU PT. LESTARI BANTEN ENERGI

Nurhadistian, Agha and Budiman, Masgunarto (2018) ANALISA DALAM PERANCANGAN INSTALASI LISTRIK MESIN CRUSHER BATUBARA DI PLTU PT. LESTARI BANTEN ENERGI. Diploma thesis, ITPLN.

[thumbnail of Agha Nurhadistian ( 2014- 11- 316 ).pdf] Text
Agha Nurhadistian ( 2014- 11- 316 ).pdf
Restricted to Registered users only

Download (9MB)

Abstract

Salah satu peralatan pendukung pembangkitan tenaga listrik adalah mesin crusher batubara. crusher batubara memecah batubara ukuran <100 mm menjadi Batubara dengan ukuran <30 mm dengan bantuan motor listrik sebagai penggeraknya. Dalam merancang instalasi listrik mesin crusher perlu diketahui persyaratan beban yang akan diputar, Kondisi lingkungan, dan persyaratan menurut persyaratan umum instalasi listrik. perhitungan-perhitungan seperti arus hubung singkat, resistansi pembumian, dan voltage drop yang dilakukan untuk mencegah kerusakan pada peralatan dan bahaya-bahaya listrik yang dapat terjadi pada manusia dan peralatan. Oleh karena itu, diperlukan pembelajaran untuk perancangan instalasi listrik sesuai dengan PUIL agar tercipta instalasi yang Listrik aman, andal, dan ramah lingkungan. Instalasi mesin crusher ini menggunakan sistem penggerak ac dengan motor induksi 264 kW dengan indeks proteksi IP 65, dan tahanan pembumian harus kurang dari 3,9146 x 10−3 Ω untuk menghindari manusia dari bahaya sentuh tidak langsung.

One of the supporting equipment for power generation is coal crusher. coal crusher breaks coal size <100 mm into coal with size <30 mm with the help of electric motor as the propulsion. In designing the electrical installation of the crusher machine it is necessary to know the load requirements to be played, environmental conditions, and requirements according to the general requirements of the electrical installation. calculations such as short-circuit current, earthing resistance, and drop voltage are performed to prevent damage to equipment and electrical hazards that may occur in humans. Therefore, it is necessary to learn to design electrical installation in accordance with PUIL in order to create a safe, reliable, and environmentally friendly electrical installation. The installation of this crusher machine uses an ac drive system with an induction motor of 264 kW with an IP65 protection index, and the earth resistance must be less than 3,9146 x 10−3 Ω to avoid humans from indirect electric touch hazards.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Perancangan Instalasi, Crusher Batubara, PUIL, Installer Designer, Coal Crusher, PUIL
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 07 Nov 2025 02:59
Last Modified: 07 Nov 2025 02:59
URI: https://repository.itpln.ac.id/id/eprint/3555

Actions (login required)