Fiqri, Dian and Widyastuti, Christine (2018) ANALISA PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP OPTIMALISASI PEMBEBANAN TRANSFORMATOR DISTRIBUSI DI PT.PLN (PERSERO) AREA CIREBON. Diploma thesis, ITPLN.
Skripsi Dian 1(5).pdf
Restricted to Registered users only
Download (1MB)
Abstract
Dalam suatu sistem 3 fasa, ketidakseimbangan beban transformator sangat sering terjadi khususnya pada sistem distribusi tegangan rendah. Karena banyaknya penambahan beban-beban listrik yang tidak memperhatikan ketidakseimbangan beban pada sistem. Pembagian beban transformator pada sisi R, S, T yang seharusnya dirancang seimbang, akan tetapi pada kenyataan yang terjadi pembagian beban nya tidak seimbang. Akibat nya pembebanan dari transformator di setiap fasa nya tidak seimbang dan apabila tidak di perhatikan dengan baik ketidakseimbangan beban pada fasa-fasa transformator dapat mengakibatkan beban lebih pada setiap fasa atau bahkan pada pembebanan transformator, serta lebih lanjut lagi terjadi rugi-rugi pada transformator tersebut dan pada sistem. Oleh karena itu masalah ketidakeimbangan beban harus diminimalisir demi mencapai kinerja optimal dari transformator. Dari hasil pengukuran transformator distribusi gardu GYGN di PT.PLN Area Cirebon yang dilakukan pada waktu beban puncak diperoleh gardu mengalami pembebanan yang overload pada salah satu fasa nya. Maka dilakukan optimalisasi dengan penyeimbangan beban pada sisi sekunder transformator distribusi setekah dilakukan perhitungan dan diperoleh persentase pembebanan transformator setelah penyeimbangan sebesar 78% dengan rincian per fasa R=77%, S=74%, dan T=81% serta persentase ketidakseimbangan beban 17,6 %.
In 3 phases system, transformers unbalanced load very often occur especially on low voltage distribution system. It happen because electricity load that’s not the same or a lot of addition on loads that doesn’t consider the unbalanced load in the system. Transformers load allocation on R, S, and T phase should balance, but in reality there will be unbalance. The results are there will be overload on every phase or even on transformers. Furthermore there will be more losses in the transformers and the system. Because of that, unbalanced load problem should be minimized to reach optimum performance. From the result of distribution transformers measurement on GYGN substation in PT. PLN Cirebon area at peak load, we can conclude that the substation already had overload on one of three phases. Then we did optimization with make balanced load on the secondary winding of distribution transformers. After some measurement, we got 78% of balanced load with details on every phase such R=77%, S=74%, and T=81% and 17.6% of unbalanced load.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Ketidakseimbangan Beban, Transformator Distribusi, Fasa, Pembebanan Unbalanced loads, Distribution Transformers, Phase, Load |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 07 Nov 2025 03:20 |
| Last Modified: | 07 Nov 2025 03:20 |
| URI: | https://repository.itpln.ac.id/id/eprint/3565 |