Perubahan beban daya aktif pada suatu sistem tenaga listrik merupakan hal yang umum, mengingat kebutuhan energi listrik pada setiap saatnya cenderung berubah. Sebagaimana pengaturan besaran daya aktif diatur dengan menambah atau mengurangi aliran uap menuju primemover (turbin) yang diatur oleh governor. Dengan melakukan pengaturan pada governor berkaitan erat dengan pengaturan daya aktif generator dan pengaturan besaran torsi poros generator. Dalam skripsi ini dibahas masalah pengaturan governor dalam kaitan Load Sharing daya aktif dengan studi kasus sistem pembangkitan PT. Pertamina RU IV. Pengaturan Governor pada sistem pembangkitan PT. Pertamina RU IV adalah droop 5% pada beberapa mesin dan Isochronous pada beberapa mesin lainnya dengan spinning reserve (cadangan putar) yang sangat besar. Skripsi ini juga membahas pengaturan poros generator dalam kaitan pengaturan daya aktif dan pembebanan generator serta efisiensi turbin generator.
Real power changes in the electrical system are commonly occurs, considering the needs on electrical energy tend to change moment to moment. As real power is adjusted by increasing or reducing the flow of the steam to the primemover (turbine) which regulated by governor. By adjusting the governor related to control the real power of generator and control the torque on generator shaft. In this thesis dissuced about governor settings in relation real power Load Sharing withal study case generation system PT. Pertamina RU IV. Governor setting on generation system PT. Pertamina RU IV are adjusted Droop 5% on several engine and Isochronous on other several engine with excessively spinning reserve. This thesis also discussed about adjustment on generator shaft torque in relation real power control and generator load along turbine generator efficiency.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Governor, Daya Aktif (MW) Governor, Real Power (MW) |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 07 Nov 2025 03:21 |
| Last Modified: | 07 Nov 2025 03:21 |
| URI: | https://repository.itpln.ac.id/id/eprint/3566 |