Bagaskara, Andhika Teja and Isworo, lakso (2018) ANALISIS SISTEM DC 110 V DI GARDU INDUK BOGOR BARU 150 KV. Diploma thesis, ITPLN.
SKRIPSI Andhika T. B..pdf
Restricted to Registered users only
Download (3MB)
5. Lembar Persetujuan Publikasi.pdf
Download (305kB)
4. Lembar Ucapan Terima Kasih.pdf
Download (258kB)
3. Lembar Keaslian Skripsi.pdf
Download (257kB)
6. Lembar Konsultasi Dosen Pembimbing.pdf
Download (288kB)
2. Lembar Tim Penguji.pdf
Download (222kB)
1. Lembar Pengesahan.pdf
Download (172kB)
Abstract
Sistem DC merupakan jantung bagi gardu induk. Sistem DC berfungsi sebagai pemberi suplai bagi peralatan utama di gardu induk, seperti rele proteksi, kontrol, meter, pemutus tenaga, dan pemisah. Penelitian ini bertujuan untuk menganalisis sistem DC di gardu induk Bogor Baru 150 KV seperti tegangan keluaran rectifier, tegangan tiap cell dan kapasitas baterai, jatuh tegangan dari pengirim ke penerima, dan sizing kapasitas rectifier dan baterai berdasarkan beban yang ada serta perbandingan dengan kondisi di lapangan. Berdasarkan perhitungan dan analisis, maka dapat diketahui untuk tegangan keluaran rectifier ke beban dari Unit 1 hingga Unit 3 adalah 117.9 V, 117.4 V, dan 115.9 V. Kemudian kapasitas baterai dari Unit 1 hingga Unit 3 sebesar 86.48%, 93%, dan 73.19% dari kapasitas awal sehingga menurut KEPDIR/0520/2014, baterai dengan kapasitas di atas 60% masih dikategorikan baik. Sedangkan untuk jatuh tegangan terbesar di ruang panel adalah Panel Interface Busbar Protection sebesar 1.52% dan di switchyard adalah Bay Ciawi 2 sebesar 3.1%. Dengan ini dapat disimpulkan jatuh tegangan berada dalam batas aman berdasarkan IEC std. 56-2 klausal 17 dan SPLN 65 1985. Dengan laporan ilmiah ini diharapkan para pembaca dapat belajar mengenai pentingnya sistem DC di gardu induk beserta standar yang mengikatnya.
DC system is the heart of substation. DC system functions as a supply for the main equipments at the substation, such as protection relay, control, meter, circuit breaker, and disconnecting switch. This study aims to analyze DC system in Bogor Baru Substation 150 KV such as rectifier output voltage,voltage per cell, battery capacity, voltage drop to the receiver, sizing capacity of rectifier and battery based on existing load, and comparison to the field. Based on calculations and analysis, it can be seen that the rectifier output voltage to the load from Unit 1 to Unit 3 is 117.9 V, 117.4 V, and 115.9 V. Then the battery capacity of Unit 1 to Unit 3 is 86.48%, 93%, and 73.19% from the initial capacity so that according to KEPDIR / 0520/2014, batteries with a capacity above 60% are still categorized as good. Whereas the biggest voltage drop in the panel room is the Busbar Protection Interface Panel of 1.52% and switchyard is Ciawi 2 Bay at 3.1%. With this it can be concluded that the voltage drop is within the safe limit based on the IEC std. 56-2 clause 17 and SPLN 65 1985.With this scientific work, we hope the reader can learn on how important of DC system in substation with the applicable standars that binding it.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | DC, gardu induk, kapasitas, jatuh tegangan, baterai. DC, substation, capacity, drop voltage, battery. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 07 Nov 2025 04:14 |
| Last Modified: | 07 Nov 2025 04:14 |
| URI: | https://repository.itpln.ac.id/id/eprint/3584 |