Andika, Elip and Isworo, lakso (2018) ANALISA KEANDALAN SISTEM TENAGA LISTRIK DI PERTAMINA REFINERY UNIT IV CILACAP. Diploma thesis, ITPLN.
Skripsi Elip Andika.pdf
Restricted to Registered users only
Download (1MB)
Lembar Pengesahan.pdf
Download (174kB)
Lembar Pengesahan Tim Penguji.pdf
Download (213kB)
Pernyataan Keaslian Skripsi.pdf
Download (241kB)
Ucapan Terima Kasih.pdf
Download (149kB)
Pernyataan Persetujuan Publikasi.pdf
Download (282kB)
Pernyataan Persetujuan Publikasi.pdf
Download (282kB)
Lampiran A Lembar Konsultasi1.pdf
Download (258kB)
Lampiran A Lembar Konsultasi2.pdf
Download (184kB)
Lampiran-B-One-Line-Diagram.pdf
Download (285kB)
Abstract
Sektor industri minyak mempunyai peran yang penting bagi perekonomian negara. Oleh karena itu, agar kilang dapat beroperasi secara aman, handal, efisien, dan berkualitas tidak lepas dari penggunaan energi listrik. Energi listrik digunakan di berbagai bagian kilang minyak, mulai dari bagian utama untuk mengolah minyak bumi maupun bagian pendukung dari kilang. Sehingga sistem pembangkit tenaga listrik dituntut memiliki keandalan yang tinggi untuk mendukung kilang minyak dapat terus berproduksi. Keandalan sistem tenaga listrik merupakan probabilitas suatu peralatan atau komponen listrik untuk mampu melakukan operasi pada periode waktu tertentu dan dalam kondisi operasi tertentu pula, sehingga dapat melayani kebutuhan tenaga listrik pada sisi beban. Guna mencapai keandalan tenaga listrik yang maksimal memerlukan adanya evaluasi. Tingkat keandalan pembangkit dihitung dengan nilai indeks LOLP (Loss Of Load Probability), EENS (Expected Energy Not Served), dan faktor keandalan pembangkit. Semakin kecil nilai LOLP dan EENS pembangkit, maka dianggap tingkat keandalan pembagkit semakin baik. Berdasarkan analisa tentang indeks keandalan pembangkit di PT. Pertamina (Persero) RU Cilacap yang dipasok oleh 8 pembangkit dengan daya tersedia 84 MW didapatkan hasil bahwa tingkat keandalan pembangkit LOLE (Loss Of Load Expectation) pada tahun 2017 adalah 15.75 hari/tahun dan EENS sebesar 2291.1 MWh/tahun.
The oil industry has an important role for the economy of the country. Therefore, in order for the refinery to operate safely, reliably, efficiently, and quality can’t be separated from the use of electrical energy. Electrical energy is used in various parts of oil refineries, ranging from main parts to processing petroleum as well as supporting parts of refineries. So that the power plant system is required to have high reliability to support the refinery can continue to produce. The reliability of an electric system is the probability that the system performs a specified operational and environmental conditions at and throughout a specified time, so it can serve the needs of electric power on the load side. In order to achieve maximum electrical reliability, it requires an evaluation. The reliability level of the power plant is calculated by the value of the LOLP (Loss Of Load Probability) index, EENS (Expected Energy Not Served), and the reliability factor of the plant. The smaller the LOLP and EENS power plant values, the higher the reliability rate the better. Based on the analysis of power reliability index at PT. Pertamina (Persero) RU Cilacap which is supplied by 8 power plants with 84 MW available result that the reliability level of LOLE (Loss Of Load Expectation) power plant in 2017 is 15.75 days / year and EENS is 2291.1 MWh / year.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Kilang Minyak, Keandalan Pembangkit, LOLP, EENS. Oil Refinery, Reliability Power Plant, LOLP, EENS. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 07 Nov 2025 08:25 |
| Last Modified: | 07 Nov 2025 08:25 |
| URI: | https://repository.itpln.ac.id/id/eprint/3590 |