Fauza, Rasya Awil and Hajar, Ibnu (2025) ANALISA KINERJA DAN EFISIENSI PENGGANTIAN KUBIKEL 20 kV DI JARINGAN DISTRIBUSI LISTRIK UP 3 KEBON JERUK. Diploma thesis, Institut Teknologi PLN.
SKRIPSI 202011131 RASYA AWIL FAUZA FINAL ,..pdf
Restricted to Registered users only
Download (3MB)
Abstract
Keandalan jaringan distribusi listrik sangat bergantung pada kondisi dan kinerja kubikel yang digunakan dalam sistem. Kubikel yang mengalami gangguan dapat menyebabkan ketidakstabilan arus listrik, meningkatkan risiko pemadaman, serta mengurangi efisiensi sistem secara keseluruhan. Oleh karena itu, penggantian kubikel menjadi langkah yang diperlukan untuk meningkatkan keandalan jaringan distribusi listrik. Penelitian ini menganalisis kinerja dan efisiensi penggantian kubikel di jaringan distribusi listrik dengan membandingkan kondisi sebelum dan sesudah penggantian. Studi ini dilakukan pada dua kasus utama, yaitu kubikel GAE- LBS (SP38 - FEDERAL) dan kubikel SIEMENS - LBS (KJ161P - AIGNER). Kedua kubikel ini mengalami gangguan signifikan, seperti macet dan kegagalan sistem proteksi, yang menyebabkan ketidakstabilan jaringan listrik. Dari segi efisiensi, penggantian kubikel memberikan manfaat dalam tiga aspek utama, yaitu efisiensi biaya, efisiensi operasional, dan efisiensi waktu. Biaya pemeliharaan berulang dapat dikurangi, keandalan sistem meningkat, serta waktu pemadaman akibat gangguan dapat diminimalkan. Selain itu, trafo yang digunakan pada kedua gardu memiliki kapasitas yang sesuai dengan standar PLN, yaitu 630 kVA untuk Gardu SP38 - FEDERAL dan 1000 kVA untuk Gardu KJ161P - AIGNER. Dengan kapasitas ini, standar arus operasional kubikel 20 kV dalam jaringan distribusi berada dalam kisaran 200A - 250A, yang sesuai dengan hasil pengukuran setelah penggantian.
The reliability of the electricity distribution network is highly dependent on the condition and performance of the cubicles used in the system. Faulty cubicles can cause electrical current instability, increase the risk of blackouts, and reduce overall system efficiency. Therefore, replacing cubicles is a necessary step to improve the reliability of the electricity distribution network. This research analyzes the performance and efficiency of replacing cubicles in the electricity distribution network by comparing conditions before and after replacement. This study was carried out on two main cases, namely GAE - LBS cubicles (SP38 - FEDERAL) and SIEMENS - LBS cubicles (KJ161P - AIGNER). These two cubicles experienced significant disturbances, such as traffic jams and protection system failures, which caused instability in the electricity network. In terms of efficiency, replacing cubicles provides benefits in three main aspects, namely cost efficiency, operational efficiency and time efficiency. Recurring maintenance costs can be reduced, system reliability increased, and outage time due to disruptions can be minimized. In addition, the transformers used at both substations have capacities that comply with PLN standards, namely 630 kVA for the SP38 - FEDERAL substation and 1000 kVA for the KJ161P - AIGNER substation. With this capacity, the standard operational current of a 20 kV cubicle in the distribution network is in the range of 200A - 250A, which corresponds to the measurement results after replacement.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Kubikel, jaringan distribusi listrik, efisiensi, keandalan, penggantian kubikel Cubicles, electricity distribution networks, efficiency, reliability, cubicle replacement |
| Subjects: | Bidang Keilmuan > Electrical Engineering Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Budi Herdiansyah |
| Date Deposited: | 10 Nov 2025 01:59 |
| Last Modified: | 10 Nov 2025 01:59 |
| URI: | https://repository.itpln.ac.id/id/eprint/3609 |