Sistem pentanahan digunakan untuk menghubungkan komponen listrik ke tanah guna menjaga perbedaan tegangan yang aman dan mencegah aliran arus ke tanah dalam segala kondisi operasional. Nilai resistensi pentanahan adalah patokan untuk instalasi listrik, dengan standar umum kurang dari 5 Ω sesuai Persyaratan Umum Instalasi Listrik (PUIL 2000). Maka dalam pengukuran dilapangan harus dijadikan acuan untuk merancang sistem pentanahan yang baik. Earth Tester digunakan untuk mengukur nilai pentanahan dan melindungi peralatan dari gangguan induksi listrik akibat sambaran petir. Pentanahan yang efektif adalah kunci dalam memastikan keamanan dan kinerja optimal instalasi listrik modern. Penelitian ini membahas tentang optimasi sistem pentanahan dengan menambahkan elektroda batang dan zat bentonite. Hasil pengukuran nilai resistansi elektroda batang dibandingkan dengan zat bentonite. Pengukuran dilakukan dengan jarak setiap 1 meter. Hasil yang diperoleh dari penelitian ini adalah zat bentonite dapat menurunkan nilai resistansi sebesar 42,5% terhadap elektroda rod yang tidak ditambahkan zat bentonite. Penambahan elektroda batang juga dapat menurunkan nilai resistansi sebesar 51,78%.
The grounding system is used to connect electrical components to the ground to maintain safe voltage differences and prevent current flow to the ground under all operational conditions. Grounding resistance value serves as a benchmark for electrical installations, with a general standard of less than 5 Ω according to the General Requirements for Electrical Installation (PUIL 2000). Therefore, field measurements must be used as a reference for designing a good grounding system. Earth Tester is used to measure grounding values and protect equipment from electrical induction interference due to lightning strikes. Effective grounding is key in ensuring the safety and optimal performance of modern electrical installations. This research discusses the optimization of the grounding system by adding rod electrodes and bentonite substance. The measurement results of rod electrode resistance values were compared with bentonite substance. Measurements were taken at intervals of 1 meter. The results obtained from this research show that bentonite substance can reduce the resistance value by 42.5% compared to rod electrodes without added bentonite substance.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Sistem Pentanahan, Zat Bentonite, Elektroda Batang Grounding System, Bentonite, Rod Electrode |
| Subjects: | Bidang Keilmuan > Electrical Engineering Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Budi Herdiansyah |
| Date Deposited: | 10 Nov 2025 02:33 |
| Last Modified: | 10 Nov 2025 02:33 |
| URI: | https://repository.itpln.ac.id/id/eprint/3616 |