Dewi, Sartika and Prianda, Prianda (2018) ANALISIS KEANDALAN SISTEM DISTRIBUSI 20KV PADA PENYULANG PAKATTO DI PT. PLN (PERSERO) AREA MAKASSAR SELATAN. Diploma thesis, ITPLN.
SARTIKA DEWI. S.pdf
Restricted to Registered users only
Download (7MB)
Abstract
Keandalan sistem tenaga listrik dapat didefinisikan sebagai suatu kemampuan sistem untuk memberikan suatu pasokan tenaga listrik yang cukup dengan kualitas yang memuaskan. Semakin meningkatnya tarif hidup masyarakat dari tahun ketahun, diikuti dengan semakin meningkatnya kebutuhan tenaga listrik. Oleh karena itu, maka dituntut daya suatu tenaga listrik yang handal. SAIDI (System Average Interruption Duration Index) akan meningkatkan keandalan subsistem, baik komponen maupun peralatan. Sementara SAIFI (System Average Interruption Frequency Index) akan menghasilkan penanganan pemadaman listrik yang lebih baik dan pengurangan waktu pemadaman. Maka dari itu, penulis akan melakukan studi rekonfigurasi pada jaringan tersebut guna memenuhi standar yang ditentukan dengan menggunakan metode deskriptif. Berdasarkan perhitungan indeks keandalan yang menghitung SAIDI dan SAIFI pada penyulang Pakatto tahun 2017 adalah SAIDI = 10,224 jam/pelanggan/tahun dan SAIFI = 2,411 pemadaman/pelanggan/tahun. Sesuai dengan SPLN 59:1985 tentang keandalan 20 kV, maka hasil Analisa SAIDI SAIFI pada penyulang Pakatto adalah handal. Gangguan yang sering terjadi adalah akibat bencana alam yang menyebabkan gangguan pada JTM maupun gardu distribusi. Potensi kehilangan pendapatan akibat pemadaman pada jaringan distribusi PT.PLN (Persero) Area Makassar Selatan tahun 2017 adalah sebesar Rp 2.041.513.246,006.
Electric power system reliability can be defined as a system's ability to provide an adequate supply of electricity with satisfactory quality. Increasing community living rates from year to year, followed by increasing electricity demand. Therefore, the power of a reliable electric power is required. SAIDI (System Average Interruption Duration Index) will increase the reliability of subsystems, both components and equipment. While SAIFI (System Average Interruption Frequency Index) will result in better handling of power outages and a reduction in blackout time. Therefore, the author will conduct a reconfiguration study on the network to meet the standards determined using descriptive methods. Based on the calculation of the reliability index that calculates SAIDI and SAIFI for Pakatto feeders in 2017 is SAIDI = 10.224 hours / customer / year and SAIFI = 2,411 outages / customers / year. In accordance with SPLN 59: 1985 regarding the reliability of 20 kV, the results of SAIDI SAIFI's analysis of Pakatto's feeders are reliable. Disruptions that often occur are due to natural disasters that cause interference with JTM and distribution substations. The potential loss of income due to blackouts in the distribution network of PT. PLN (Persero) South Makassar Area in 2017 is Rp. 2,041,513,246,006
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Analisa Keandalan, SAIDI, SAIFI. Reliability Analysis, SAIDI, SAIFI. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 10 Nov 2025 06:17 |
| Last Modified: | 10 Nov 2025 06:17 |